background image

14 

18

 

X

X

N

N

E

E

T

T

 

 

N

N

e

e

t

t

w

w

o

o

r

r

k

k

 

 

B

B

o

o

x

x

 

 

C

C

a

a

m

m

e

e

r

r

a

a

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 

 

Enter the user name and password to bring up the web viewer page. The default id and password is “

root

”, 

admin

” respectively. If you want to use a different HTTP port number from the default value, simply put a 

colon and port number at the end of the IP address. (For example, enter the following address when 
changing the port to 8080: 

http://192.168.123.100:8080

<Address format for accessing as an administrator> 

(When using default IP address and port number)     

 http://192.168.123.100 

(When IP address and port number changed)           

http://IP address: new port number 

 

 
 

 

 

If you forget the administrator’s password, “Factory Reset” is the only way to regain 

access. However, since this will retrieve all default settings, the network settings 
have to be configured again using the IP installer. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

For security, please change the administrator’s id and password from their default 
values. Please save the changed ID and password in a place only accessible by an 
administrator. Please refer to 

[

Web Viewer Manual] 

for detail

Summary of Contents for IGB1110PF

Page 1: ...Ver 1 0 XNET Network Box Camera IGB1110PF IGB1110NF Installation Manual...

Page 2: ...rer immediately if you think there is any problem with the product Contact the store or the manufacturer before disassembling the product for alteration or repair XNET is a trademark of CNB Technology...

Page 3: ...ct 5 2 1 Contents 5 2 2 Product Information 5 2 3 Functions and Designations 6 2 3 1 Side View 6 2 3 2 Rear View 7 2 3 3 Connecting to Alarm devices 9 3 Software Installation 10 3 1 Connecting XNET to...

Page 4: ...pplications of network or user 2 way Audio Communication Bi directional voice communication between Client s PC and XNET Smart Event feature On the top of motion detection and sensor alarm feature pre...

Page 5: ...Camera Lens not included Auto Iris Lens Plug Connection plug for Auto Iris control signal Power adapter Input 100 240VAC 50 60Hz Output 12VDC 2A AC power Cord 2 jack cable CD Software and User s manua...

Page 6: ...ount Fixed or Vari Focal DC Auto Iris lens yAuto Iris Control Plug Plug for Auto Iris control The following shows each pin connection Strip 8mm of outer jacket of the lens cable and then strip 2 mm of...

Page 7: ...r Amplified device or Speaker This can be used to listen to the audio signal sent from a remote PC for Bi directional Audio communication VIDEO OUT Use this output to monitor the analog video signal w...

Page 8: ...in Description Set up 1 Alarm Out Select NC NO at menu screen 2 Alarm Out 3 Alarm In Select NC NO at menu screen 4 Alarm In 5 RS485 6 RS485 RS 485 When properly connected you can remotely control Pan...

Page 9: ...shown in figure 2 5 NC or NO of sensor input can be selected at Menu screen Alarm Sensor device requires a separate power source Alarm in Alarm in Photo Coupler Sensor Device Signal 5 30VDC GND Adapt...

Page 10: ...rk k 1 A PC or a laptop computer is required to set up an IP address z Compatible operating system Windows 2000 Windows XP Windows Vista z Since the default IP address of the device is 192 168 123 10...

Page 11: ...a and monitoring PC to a network IP Installer software provided in the Installation CD included in the package and also available to download from our website http www cnbtec com will configure IP add...

Page 12: ...h you wish to change the IP address and click Set IP Address button to bring up the following box in Figure 3 3 Figure 3 3 IP Address box 3 When you enter the IP address and click Set button the box s...

Page 13: ...T CMS software This manual explains about using internet web browser only For instructions on how to configure network connection using XNET CMS software please refer to XNET CMS Manual which can be f...

Page 14: ...http 192 168 123 100 8080 Address format for accessing as an administrator When using default IP address and port number http 192 168 123 100 When IP address and port number changed http IP address n...

Page 15: ...k B Bo ox x C Ca am me er ra a I In ns st ta al ll la at ti io on n M Ma an nu ua al l 4 4 2 2 W We eb b V Vi ie ew we er r P Pa ag ge e Web viewer page consists of Video monitor screen and menu opti...

Page 16: ...IP camera and control of PTZ movement Please refer to XNET Owner s Manual for detail Motion Detection Opens up Motion Detection page You can add or delete areas for detecting motion in this page Plea...

Page 17: ...ol On Off 8 zone settings over IP Stabilizer On Off D Effect V Flip Mirror Rotate Electronic Shutter Speed 1 60 1 90 000 Sec 1 50 1 90 000sec Video Audio Compression MJPEG MPEG4 H 264 Frame rate Singl...

Page 18: ...cal storage Internal memory or SD card memory JPEG image Applications Browser Internet Explorer 6 0 or later Monitoring Application CNB NVR CNB CMS and Utility IP Installer etc Maintenance System Upgr...

Reviews: