5.1 - Inspection

Each individual component of the automation, e.g. sensitive edges, photocells,
emergency stop etc requires a specific inspection phase. For these devices the
procedures given in the respective instruction manuals must be performed.
For the X-Metro inspection, proceed as follows:

1

Check that everything envisioned in chapter 1 - General safety warnings
and precautions, is rigorously respected;

2

Close the gate;

3

Remove any electric power input source to the control unit;

4

Release the gear motor using the relative wrench, see paragraph 3.6;

5

Open the panel manually until the maximum opening position is reached
and check that there is no friction during the movement;

6

Check that the panel, left in any position of its run, does not move;

7

Check that the safety systems and the mechanical stops are in good work-
ing order;

8

Check that the screw connections are well-fastened;

9

If necessary, clean the inside of the foundation case and check that the
water drain functions correctly;

10

Block the gear motor using the relative wrench, see paragraph 3.6;

11

Apply the electric power input to the control unit;

12

Measure the force of impact according to that envisioned by the EN 12445
Standard. If the control of the “driving force” is used by the control unit as
an auxiliary to the system for the reduction of the force of impact, try and
adjust the functions that offer better parameters;

13

Permanently fix a label, which describes how to manually release the gear
motor, in a zone adjacent to the automation.

5.2 - Commissioning

Commissioning can only be performed after all of the inspection phases of the
gear motor and other devices present have been performed with positive
results. For commissioning refer to the control unit instruction manual.

IMPORTANT –

Partial commissioning or in “temporary” situations is

prohibited

.

In general the automation requires periodical maintenance so that it can func-
tion as long as possible in complete safety. The maintenance of the automation
must be programmed with periodic frequency. Maintenance programmed at
maximum every 6 months is necessary.

To perform maintenance checks, repeat the procedure described in chapter
5.1 - Inspection.

Important!

– Before carrying out any check, disconnect any electrical

power input source.

PRODUCT MAINTENANCE

6

DISPOSAL OF THE PRODUCT

This product is an integral part of the automation and therefore must be
demolished with it.

As for installation, the plant must also be demolished by qualified staff at the
end of its life span.
This product is made up of various types of materials: some can be re-cycled,
others must be disposed of. Obtain information regarding recycling or disposal
systems envisioned by the Standards in force on your territory for this category
of product.

Attention!

– some parts of the product can contain pollutant or dangerous

substances which, if dispersed into the environment, could have damaging
effects on the same and human health.

As indicated by the symbol at the side, it is prohibited to throw
this product into domestic waste. "Separate collection" must
be performed for disposal, according to the methods envi-
sioned by the Regulations in force on your territory or take the
product back to your dealer on the purchase of a new equiva-
lent product.

Attention!

– local regulations in force may envision heavy

sanctions if this product is disposed of abusively.

RECOMMENDATIONS: •

All technical features stated make reference at a room temperature of 20°C (± 5°C). • Nice S.p.a. reserves the right to modify the pro-

duct at any time it deems necessary, however maintaining the same functionality and destination of use.

Type

Electro-mechanical dear motors for gates and doors with hinged panels

Power input

24 V

Peak absorption

5 A

Maximum absorption

2 A

Peak power

120 W

Maximum power

50 W

Protection rating

IP 67

Run

from 0° to 90° (±10°) or from 0° to 180° (±10°) [intermediate openings between 90° and 180° are not possible]

Idle speed

1.25 rpm

Speed at nominal torque

1 rpm

Maximum torque

250 Nm

Nominal torque

120 Nm

Functioning temperature

from -20 °C to +50 °C

Cycles/hour at the nominal torque

60

Duration

Estimated between about 80,000 and 200,000 manoeuvre cycles, according to the conditions given in Table 1

Dimensions

230 mm x 206 mm x h 88 mm

Weight

15 Kg (gear motor with foundation space)

PRODUCT TECHNICAL FEATURES

ISTXME.4865 Rev00 Xmetro_ok.qxd:Layout 1

25-06-2009  11:45  Pagina 3

Summary of Contents for XME2024

Page 1: ...avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und Hinweise PL Instrukcje i ostrze enia do...

Page 2: ......

Page 3: ...tarting work affix a sign onto the disconnection device that states ATTENTION MAINTENANCE IN PROGRESS Handle the automation with care during installation preventing crushing blows falls or contact wit...

Page 4: ...end 1 1 5 1 8 2 2 3 100 250 300 330 400 LUNGHEZZA MAX ANTA m PESO MAX ANTA Kg PANEL MAX WEIGHT Kg PANEL MAX LENGTH m EN 2 English Recommendations The gear motor is supplied with an electric power inpu...

Page 5: ...ogrammed at maximum every 6 months is necessary To perform maintenance checks repeat the procedure described in chapter 5 1 Inspection Important Before carrying out any check disconnect any electrical...

Page 6: ...ns of the Member States relative to electromagnetic compatibility and which repeals the 89 336 EEC Directive According to the following harmonised Standards EN 61000 6 2 2005 EN 61000 6 3 2007 Moreove...

Page 7: ...VIII 254 mm 72 5 mm 320 mm 81 mm 52 mm 1 3 4 2 A G G G C D D E F H C B A...

Page 8: ...IX 1 2 5 6 7 8...

Page 9: ...X 9 10 90 90 180...

Page 10: ...XI 11 12 13...

Page 11: ...XII Clack 1 2 3 14 15...

Page 12: ...XIII 4 5 1 2 3 16 180 17 A B C...

Page 13: ...ance Buchelay France Ph 33 0 1 30 33 95 95 Fax 33 0 1 30 33 95 96 info fr niceforyou com Nice France Sud Aubagne France Ph 33 0 4 42 62 42 52 Fax 33 0 4 42 62 42 50 infomarseille fr niceforyou com Nic...

Reviews: