U
SE
R
M
AN
AL
N
S6
/N
S1
2P
F
USER MANUAL
XLNT
DataMotion
NS6
NS12P
NS12PF
ETHERNET SWITCHES
Page 1: ...USER MANUAL NS6 NS12P NS12PF USER MANUAL XLNT DataMotion NS6 NS12P NS12PF ETHERNET SWITCHES...
Page 2: ...89 336 EEC Electromechanical Contamination Directive 2006 95 EEC Low Voltage Directive IEC 60950 1 2005 mod Safety of Information Technology Equipment including Electrical Business Equipment EN55022 1...
Page 3: ...on Directive 2006 95 EEC Low Voltage Directive IEC 60950 1 2005 mod Safety of Information Technology Equipment including Electrical Business Equipment EN55022 1998 A1 2000 A2 2003 Information technolo...
Page 4: ...d in any way such as power supply cord or plug being damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate norma...
Page 5: ...ified as AEL Class I U S 21 CFR J and AEL Class 1 per EN 60825 1 A11 They are eye safe under normal operating conditions and under all reasonably fors eeable single fault conditions per EN60825 1 TUV...
Page 6: ...tion Application Features Products Power over Ethernet Copper Ethernet cabling Fiberoptic Ethernet Cabling Chapter 2 Using the NS6 Included Items Front Panel layout Installation requirements Connectin...
Page 7: ...t Rear Panel layout Installation requirements Connecting Ethernet Power Requirements LED signals Chapter 5 Troubleshooting Power Data Hardware Failure Diagnostic NS12P NS12PF Only Appendix 1 Maintenan...
Page 8: ...ntact your local XLNT dealer Please do not send equipment to XLNT without authorisation If asked to do so please add a copy of the original invoice together with the faulty device in a secure shipping...
Page 9: ...port so if multiple devices are used on a single location an Ethernet switch must be used to connect these to eachother Features The DataMotion Ethernet switch product line comprises 3 models All of t...
Page 10: ...rises 3 models NS6 Ethernet switch 6 way 10 100 Mb Ethernet Switch Power and data input via separate Power over LAN port according to 802 3AF Trussmountable housing Ethernet ports are fitted with Neut...
Page 11: ...thernet ports are fitted with Neu trik EtherCon connectors NS12PF Ethernet switch 12 way 10 100 Mb Power Over LAN switch 100 240V input with 2 1Gb fiberoptic ports Housing is 19 rack mounted 1HE Ether...
Page 12: ...ion procedure a PoE classification will be sent This classification determines how much power will be required and allocated The output power per port is higher than the maximum consumption to allow f...
Page 13: ...cable is a minimum requirement Maximum operational cable lenghts are typically 95 metres with UTP unschielded twisted pair cables 50m with SFTP shielded foil twisted pair FTP foil twisted pair or STP...
Page 14: ...wing items should be present 1 XLNT NS6 Ethernet switch with integral bracket and safety 1 Manual this manual Front Panel layout Chapter 2 Using the NS6 1 Power LED 1 2 Power LED 2 3 10 100 Mbit Power...
Page 15: ...Ethernet switch Mount this clamp onto the bracket which is attached to the NS6 Ethernet switch with M10 Nylock nuts and M10 bolts It may be required to remove the bracket Please observe the position...
Page 16: ...a Midspan Power Inserter The NS6 Ethernet switch is a Class2 PoE device See table on page 13 for specifications LED signals Power LED 1 The upper LED shows the status of the 5V power supply to the con...
Page 17: ...18 USER MANUAL NS6 NS12P NS12PF This page intentionally blank...
Page 18: ...ollowing items should be present 1 XLNT NS12P Ethernet switch 1 Manual this manual 1 Power lead Front Panel layout 1 Power LED 1 2 Power LED 2 3 10 100 Mbit Power over Ethernet port 3 1 Ethernet port...
Page 19: ...ntilation into the 19 cabinet in which the NS12PF Ethernet switch is mounted Observe the environmental specifications at all times When mounting a NS12PF Ethernet switch in a touring rack a touring ra...
Page 20: ...t be connected to a 100 240V 50 60Hz electrical power supply with a single phase neutral and ground connection For safety reasons the NS12PF Ethernet switch must be connected to a properly grounded po...
Page 21: ...s detected maxi mum allocatable power reached this LED will blink intermittendly with 2 pulses Duplex Collision per port When a full duplex network connection is negotiated this LED will be lit This L...
Page 22: ...et switch 1 Manual this manual 1 Power lead Front Panel layout 1 Power LED 1 2 Power LED 2 3 10 100 Mb Power over Ethernet port 3 1 Ethernet port 3 2 LED 1 Power over Ethernet active 3 3 LED 2 Duplex...
Page 23: ...tilation into the 19 cabinet in which the NS12PF Ethernet switch is mounted Observe the environmental specifications at all times When mounting a NS12PF Ethernet switch in a touring rack a touring rac...
Page 24: ...mm Maximum operational cable length is typically 550 metres without couplers 1000BASE SX Multimode Please use caution when bending fiberoptic cable This type of cabling is very sensitive to excessive...
Page 25: ...it or overload is detected this LED will be blinking intermittendly with one pulse When an overload is detected maxi mum allocatable power reached this LED will blink intermittendly with 2 pulses Dupl...
Page 26: ...this cable is properly wired all pins connected in the proper order and undamaged Use a different cable Connect the NS6 Ethernet switch to a different port or a dif ferent switch If no LED s are lit c...
Page 27: ...et switch wait 10 seconds and apply power again Immediately all LED s should be lit for 1 second If a single or more LED is lit for 5 seconds one or more of the following faults may occur If any of th...
Page 28: ...being used always use the cover to protect the connector against dirt and mois ture Servicing Do not open this unit Doing so will void warranty and might present a risk Servicing must be performed by...
Page 29: ...3 0 Kg Weight physical NS12PF 3 2 Kg Ingress protection rating IP20 NS12P NS12PF Electrical Input voltage frequency 100 240V AC 50 60Hz Power rating 120 Watt max Fuse 2 5 A SlowBlow 20 x 5mm Environm...
Page 30: ......
Page 31: ...USER MANUAL NS6 NS12P NS12PF International Sales office XLNT Advanced Technologies Tel 31 30 247 99 99 Fax 31 30 247 99 98 info xlnt at com www xlnt at com Manual rev 2 0 Jan 2008...