Channel
DMX512 code
Control content
Vertical roll
0–127
Manual vertical roll
128–255
Automatic roll
Horizontal roll
0–127
manual horizontal roll
128–255
Automatic roll
Rotation
0–127
manual rotate
128–191
Automatic rotate deasil
192–255
Automatic rotate anticlockwise
Zoom
0–85
Zoom in
86–170
Zoom out
171–255
ZOOm
size
0–255
Original size-0,MIN-1,MAX-255
Point-Draw
0–255
No point-0,mIN-1,maX-255
Point-Draw
0–127
The first Point-Draw
128–255
The second Point-Draw
Note:
• The best temperature to use the device ,the range: 20~35°;
• Do not make the laser beam directly to the human eye, to avoid eye damage;
• Do not touch the lens of the projector;
• Inside high-pressure, be careful.
CoMMon TroubleShooTing TAble
Note:
If the fault still can not be excluded, please contact your local dealer or the factory.
reaction
Fault cause
The solution
No reaction
The power is off.
The fuse is broke
Connect the power supply, and change the new fuse
The brightness
is weak
The diode has time
to warm-up
To warm up for 5-10 mins
The lens is dirty,
oil stains
With a soft cotton swab dipped in absolute alcohol
to clean the lens
No beams the
fans and scanner
are working well
The address code
switch is not correct
The address code is set to the correct location
Sound sensitivity
adjustment is too low
or no sound trigger
adjust the voice knob and open the music