background image

4

X GLOO

®

  

  Windeckstr. 4  

  83250 Marquartstein  

  Deutschland

1. TECHNICAL DATA

 

XC 3 

XD 4 

XD 5 

XD 6 

Exterior side length 

3,0 m 

4,0 m 

5,0 m  

6,0 m

Entrance height 

1,95 m 

2,0 m 

2,5 m 

3,0 m

Total height 

2,6 m 

2,38 m 

3,0 m 

3,57 m

Tube diameter 

20,0 cm 

25,0 cm 

31,0 cm 

37,0 cm

Weight without Walls 

9,32 kg 

13,3 kg 

18,8 kg 

22,5 kg

COVERED AREA

without Side Walls 

5,6 m2 

7,23 m2 

11,3 m2 

16,27 m2

with 4 Canopies 

23,0 m2 

35,7 m2 

51,34 m2

SETUP

Hand Pump 

10 min 

15 min 

25 min 

30 min

Electric Pump 

3-5 min 

3-5 min 

7-10 min 

10-15 min

Operating pressure* 

0,35 bar/ 

0,35 bar/ 

0,26 bar/ 

0,26 bar/ 

 

5,1 PSI 

5,1 PSI 

3,8 PSI 

3,8 PSI 

*This data serves primarily as information, since the operation of the overpressure valves is automatic.

All dimensions are approximate.

Entr

anc

e height

To

tal height

Tube 

diameter

Covered area

Exterior s

ide length

Exterior s

ide length

2

Summary of Contents for XC 3

Page 1: ...D Lighting Kit Tubes Roof XD 6 XD 5 Tunnel Part XD 7 Standard Wall Window Wall Entrance Wall Entrance Wall Window Wall Standard Wall Stool Wall Ballast Tube Ballast Ballast Barrel XC 3 XC 3 USER MANUAL XC XD SERIES TENTS QUICK USER GUIDE ...

Page 2: ...COVERED AREA without Side Walls 5 6 m2 7 23 m2 11 3 m2 16 27 m2 with 4 Canopies 23 0 m2 35 7 m2 51 34 m2 SETUP Hand Pump 10 min 15 min 25 min 30 min Electric Pump 3 5 min 3 5 min 7 10 min 10 15 min Operating pressure 0 35 bar 0 35 bar 0 26 bar 0 26 bar 5 1 PSI 5 1 PSI 3 8 PSI 3 8 PSI This data serves primarily as information since the operation of the overpressure valves is automatic All dimension...

Page 3: ...2 1x Hand pump 3 1x User manual and quick user guide 4 1x 5 mm Allen key 5 1x 4 mm Allen key 5 1x cable tie 6 1x Valve wrench 7 1x Valve adapter 8 1x Replacement bladder 9 XD 5 6 7 1x Anchoring line set 1 3x Repair kit 2 1x Hand pump 3 1x User manual and quick user guide 4 1x 5 mm Allen key 5 1x 4 mm Allen key 5 1x cable tie 6 1x Valve wrench 7 1x Valve adapter 8 1x Replacement bladder 9 1x Closin...

Page 4: ...vable protective covers on the tube ends protect the tent from damage Therefore in order to prevent leaks it is strongly recommended to reattach the protective covers before folding up the tent 3 2 INFLATION DEFLATION VALVES RAISING The valve for inflation deflation consists of the socket that is permanently welded to the inner tube and a screw on valve housing with attached protective cover 3 2 1...

Page 5: ...nt to use it 3 2 2 INFLATION XD 4 5 6 7 WITH ONE PUMP SYSTEM PLEASE NOTE Before inflating be sure that the backflow preventers on the valves found on the inner side of each tube are closed in the up position To inflate use the central inflation hose which can be found on the outer side of one of the four tubes Connect one end of the hose to the pump and the other end to the inflation hose by means...

Page 6: ...vent the valve from functioning correctly 3 2 4 RAISING XC 3 XD 4 5 6 7 PLEASE NOTE Raising the tent from the ground requires some assistance Before the tubes are fully inflated the middle of the tent where the tubes intersect must be actively lifted off the floor This prevents the tent from possibly being damaged from being inflated invertedly When setting up the tent in sandy terrain make sure t...

Reviews: