page 8 of 8
The
Loop Back Cable Fitted
option is selected and greyed out as the Carrier Board will automatically
apply the required loopback.
When running the self-test from the integration DLL use the Test method on the XJLink object specifying a
value of true for the
runLoopBackTest
parameter.
9. Carrier Board Electrical and Operational Specifications
10. Handling Procedures
In all cases, it is assumed that the Carrier Boards and XJLink2-3030 modules are handled by personnel
XJTAG-3030-Guide-20C-01
www.xjtag.com
SPEA 3030 XJLink2 Carrier Board
.
User Guide
Outer dimensions (including connectors)
342 mm length x 369 mm width x 11 mm height
Nominal PSU operating Voltage
24 VDC (± 5%)
Minimum PSU operating Voltage
12 VDC
PSU source
External (SPEA 3030 system)
PSU Under voltage lockout value
Approximately 10 V
Current consumption (No modules in place)
Approximately 17 mA (24 VDC PSU input)
Current consumption (1 module, relays not active)
Approximately 41 mA (24 VDC PSU input)
Current consumption (2 modules, relays not active)
Approximately 64 mA (24 VDC PSU input)
XJLink2 data connection
Single approved USB cable (normal B-type)
Maximum number of fitted XJLink modules
2
System Test connector
72-way double-row right angle 0.1 inch pitch connector
Digi-key # TSS-136-04-L-D-RA-ND