background image

Part Number

 

18143,

 

E, 01/28/2020 

 
 
 
 

 
 

Propane Fume Detection System 

With Solenoid Valve Control 

 
 
 
 

Single Channel Systems 

P-1BS-R (Black, Round, Solenoid Control, 12V Solenoid) 

P-1BS-24-R (Black, Round, Solenoid Control, 24V Solenoid) 

P-1CS-R (Chrome, Round, Solenoid Control, 12V Solenoid) 

P-1CS-24-R (Chrome, Round, Solenoid Control, 24V Solenoid) 

 

Dual Channel System 

P-2BS-R (Black, Square, Solenoid Control, 12V Solenoid) 

P-2BS-24-R (Black, Square, Solenoid Control, 24V Solenoid) 

 
 
 
 

Owner’s Manual

 

Installation Instructions 

 
 
 

 

Read and comply with all instructions, warnings and limitations before 

installing, servicing or removing this device. 

 
 

Summary of Contents for P-1BS-24-R

Page 1: ...rol 24V Solenoid P 1CS R Chrome Round Solenoid Control 12V Solenoid P 1CS 24 R Chrome Round Solenoid Control 24V Solenoid Dual Channel System P 2BS R Black Square Solenoid Control 12V Solenoid P 2BS 24 R Black Square Solenoid Control 24V Solenoid Owner s Manual Installation Instructions Read and comply with all instructions warnings and limitations before installing servicing or removing this devi...

Page 2: ...stalling the Display Unit P1BR S01 D P1CR S01 D P2BS S01D 6 Installing the Solenoid Valve for LPG Applications 6 Routing Sensor Cable s FS X01 CABLE XX 6 Installing Propane Fume Sensor s FS T01 7 Electrical Connections P1BR S01 D P1CR S01 D P2BS S01D 7 Testing the System Operation 7 Testing the Propane Fume Sensors 8 Maintenance 8 In the Event of an Alarm 8 Repairing Xintex Propane Detection Compo...

Page 3: ...he system Specification System Specifications P 1BS R P 1CS R Operating Voltage 9 18V DC Nominal Current Draw 55mA 12V DC Maximum Current Draw 725mA 9V DC Operating Temperature 40 F 40 C to 185 F 85 C Alarm Horn 68 dB System Specifications P 1BS 24 R P 1CS 24 R Operating Voltage 18 30V DC Nominal Current Draw 25mA 24V DC Maximum Current Draw 41mA 18V DC Operating Temperature 40 F 40 C to 185 F 85 ...

Page 4: ...he bottom indicates a fume buildup of 20 of the LEL Lower Explosive Limit which is considered an alarm The alarm horn will sound when the Red LED is illuminated The alarm horn will actuate Solenoid Valve will close and the Solenoid Valve status LED will deactivate when the Red LED is illuminated Whenever the Solenoid Valve status LED is illuminated the Solenoid Valve is open The alarm status will ...

Page 5: ...ker 2A May be obtained Display Unit 2A fuse recommended Solenoid Valve YELLOW Switching Ground 2A Fuse Included FS X01 CABLE XX FS T01 FS X01 CABLE XX FS T01 P2BS S01 D RED Power 1 0 Amp Fuse from Circuit Breaker BLACK Ground Solenoid Valve YELLOW Switching Ground 2A Fuse Included Positive voltage From Solenoid Circuit Breaker 2A May be obtained Display Unit 2A fuse recommended ...

Page 6: ...actical The tank itself should be mounted outside the cabin or crew quarters to avoid the possibility of gas accumulation due to a leak NOTE TIGHTEN TO 12 13 FT LBS DO NOT OVER TIGHTEN NOTE ALL PIPING MUST BE CHECKED FOR LEAKS USE SOAPY WATER SOLUTION ON ALL JOINTS NEVER USE A FLAME TO CHECK FOR LEAKS Routing Sensor Cable s FS X01 CABLE XX A 20 FT Sensor Cable is provided for each Propane Fume Sen...

Page 7: ...fused Yellow 16 GA wire is provided for connecting the Display Unit to the Solenoid Valve Connect the Yellow wire to the Solenoid Valve Connect the positive voltage to the Solenoid Valve NOTE UNITS MANUFACTURED PRIOR TO JANUARY 01 2018 DO NOT INCLUDE THE 2A FUSE A DEDICATED 2A FUSE OR BREAKER SHOULD BE USED TO POWER THE SOLENOID VALVE NOTE IMPROPER CONNECTIONS WILL DAMAGE THE DISPLAY UNIT AND WILL...

Page 8: ...engers and crew exit the passenger compartment and vessel if possible Ventilate the space being monitored Carefully check all fuel lines and other potential sources of propane fume leaks If leaks are identified shut off fuel supply and make any necessary repairs Repairing Xintex Propane Fume Detection Components Xintex Propane Fume Detection Components are not field serviceable Components must be ...

Page 9: ...ment of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental costs which may arise as a result of any defect in material or workmanship and e upon discovery of defect Buyer shall immediately cease use of and notify Fireboy Xintex LLC Any warranty implied by law ...