7
Part Number
18150, E, 02/07/2018
Specifications
System Specifications (CMD5-RB & CMD5-RB-B)
Operating/Storage Temperature: -40°F (-40°C) to 158°F (70°C)
Alarm Points: Time Weighted Average (TWA)
Alarm @ 10% COHb (<15min @ 400 PPM)
Alarm Horn: ≈ 85dB @3.05M
Dimensions: 3.5” (89mm) x 3.5” (89mm) x 1.25” (32mm)
Housing Material: Polylac PA-765(ABS-FR)
System Specifications (CMD5-RBI & CMD5-RBI-B)
Operating/Storage Temperature: -40°F (-40°C) to 158°F (70°C)
Alarm Points: Time Weighted Average (TWA)
Alarm @ 10% COHb (<15min @ 400 PPM)
Alarm Horn: ≈ 85dB @3.05M
Dimensions: 3.5” (89mm) x 3.5” (89mm) x 1.25” (32mm)
Housing Material: Polylac PA-765(ABS-FR)
System Specifications (CMD5-RD & CMD5-RD-B)
Operating Voltage: 9-32 VDC
Nominal Current Draw -40°F (-40°C) to 158°F (70°C): 1mA
Maximum Current Draw -40°F (-40°C) to 158°F (70°C): 3mA
Operating/Storage Temperature: -40°F (-40°C) to 158°F (70°C)
Alarm Points: Time Weighted Average (TWA)
Alarm @ 10% COHb (<15min @ 400 PPM)
Alarm Horn: ≈ 85dB @3.05M
Dimensions: 3.5” (89mm) x 3.5” (89mm) x 1.25” (32mm)
Housing Material: Polylac PA-765(ABS-FR)
System Specifications (CMD5-RDI & CMD5-RDI)
Operating Voltage: 9-32 VDC
Nominal Current Draw -40°F (-40°C) to 158°F (70°C): 1mA
Maximum Current Draw -40°F (-40°C) to 158°F (70°C): 3mA
Operating/Storage Temperature: -40°F (-40°C) to 158°F (70°C)
Alarm Points: Time Weighted Average (TWA)
Alarm @ 10% COHb (<15min @ 400 PPM)
Alarm Horn: ≈ 85dB @3.05M
Dimensions: 3.5” (89mm) x 3.5” (89mm) x 1.25” (32mm)
Housing Material: Polylac PA-765(ABS-FR)
NOTE:
THE REPLACEMENT DATE THAT APPEARS ON THE DEVICE IS THE DATE BEYOND WHICH THE
DEVICE MAY NO LONGER DETECT CARBON MONOXIDE ACCURATELY AND SHOULD BE REPLACED.
CONSTANT EXPOSURE TO HIGH OR LOW HUMIDITY CAN REDUCE BATTERY LIFE.