background image

 

8

• 

Wear a dust mask.  

Additional safety rules:

 

1. Wear a hard hat (safety helmet), safety glasses and /or face shield. It is also highly recommended that 

you wear a dust mask, ear protectors and thickly padded gloves.

 

2

Be sure the bit is secured in place before operation.

 

3. Under normal operation, the machine is designed to produce vibration, the screws and bolts can come 
loose, causing a breakdown and accidents. Check tightness of them carefully before running.

 

4

In cold weather or a long time tool not be used, please keep the tool running without load a few 

minutes to warm up the grease inside, otherwise hammering function is difficult to get.

 

5

Be sure you stand stably and no one is below when you using tool is in high location.

 

6

Hold the tool firmly with two hands.

 

7

Don't touch any moving parts.

 

8

Don't leave the tool running itself, operate tool only when hand-held.

 

9

Don't point the tool to anybody for the bit could fly out in case.

 

10

When chipping into walls, floors or wherever "live"    electrical wire may be encountered, 

DON'T TOUCH ANY METAL 

PARTS OF THE TOOL! Hold the tool by the insulated 

grasping surface to prevent electric shock if you chip into a "live" wire. 

11

Don't touch the BIT OR PARTS CLOSE TO THE BIT immediately after operation, they may 

extremely hot and could burn your skin.

 

12

Any damage and abnormal happen, please stop to use immediately and disconnect it, ask authorized 

serve center to check and repair.

 

13. Parts replace:

 Only original XINPU's parts can be used to replace by authorized service center.

 

14. Right use accessories and parts:

 Don't use other parts and accessories which not mentioned in the 

manual otherwise may cause injuries!

 

15. Special attention to voltage:

 Before connect the power tool, please make sure the rated voltage on 

the tool can match the power supply, otherwise the power tool may be damaged and cause injuries.

 

16. Don't wipe plastic part with solvent: 

Solvent such as gasoline, thinner, alcohol etc. these kind of 

chemical material,    are not allowed to use, water or soap are recommended! 
17. In case of damages the replacement of the plug or the supply cord shall always be carried out by the 
manufacturer of the tool or his service organization 
 

Residual risks 

Even when the power tool is used as prescribed it is not possible to eliminate all residual risk factors. 
The following hazards may arise in connection with the power tool’s construction and design: 

a)

 

Injuries and damage to property to due to broken accessories that are suddenly dashed.   

b)

 

Health defects resulting from vibration emission if the power tool is being used over longer period of 
time or not adequately managed and properly maintained. 

c)

 

Lung damage if don’t use dusk mask.   

d)

 

Hearing damage if don’t use ear protection. 

 

Warning! 

This power tool produces an electromagnetic field during operation. This field may under 

some circumstances interfere with active or passive medical implants. To reduce the risk of serious or 
fatal injury, we recommend persons with medical implants to consult their physician and the medical 
implant manufacturer before operating this power tool. 

Summary of Contents for XP-G65BH

Page 1: ...the machine works and how it should be operated Maintain the machine in accordance with the instructions and make certain that the machine work correctly please store this instriation and other enclosed documents with the machine togeth Bj 2012 Zhejiang Xinpu Industrial Commercial Co Ltd 106 No 330 National Road Huajie Industrial Zone Yongkang City Zhejiang 321300 P R China ...

Page 2: ...ccordance with 2000 14 EC 105 6dB A Guaranteed Sound power values in accordance with 2000 14 EC 106dB A Vibration Main handle ah Cheq 15 340m s2 k 1 5m s2 Auxiliary handle ah Cheq 12 028m s2 k 1 5 m s2 Note Noise and vibration values are determined acc to EN 60745 1 and EN 60745 2 6 Note The declared vibration value has been measured in accordance with a standard test method and may be used for co...

Page 3: ...ce Amphibious screwdriver 1 piece One bottle of grease 60g Bull point chisel 28 410mm 1 piece flat chisel 28 410mm 1 piece Carbon brush 7 17 18mm 1 couple Optional accessories sold separately Notice Optional accessories sold separately are recommended only for XINPU tool for specified purpose in manual any other brand accessories or attachments used may present risk of injury 1 Bull point Hexagon ...

Page 4: ...8 410 length Unit mm Tooth distance 12mm Tooth high 8mm Length width 60 60mm 6 Tamping plate Shank Hexagon size28 394 length Unit mm Length width 150 150mm 7 Big flat spade Shank Hexagon size28 296 length Unit mm Length width 170 150mm 8 Square spade Hexagon size28 440 length Unit mm ...

Page 5: ...life or damage to the tool in case of nonobservance of the instruction in this manual Indicate electrical shock hazard Immediately unplug the plug from the main electricity in the case that the cord gets damage and during maintenance Wear ear and eye protection Faulty and or discarded electrical or electronic apparatus have to be collected at the appropriate recycling location The guaranteed Noise...

Page 6: ...ed or grounded c Do not expose power tools to rain or wet conditions Water entering a power tool will increase the risk of electric shock d Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an ext...

Page 7: ...do not allow persons unfamiliar with the power tool or these instructions to operate the power tool Power tools are dangerous in the hands of untrained users e Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tools operation If damaged have the power tool repaired before use Many accidents are caused by poorl...

Page 8: ...e Only original XINPU s parts can be used to replace by authorized service center 14 Right use accessories and parts Don t use other parts and accessories which not mentioned in the manual otherwise may cause injuries 15 Special attention to voltage Before connect the power tool please make sure the rated voltage on the tool can match the power supply otherwise the power tool may be damaged and ca...

Page 9: ...oser 7 Switch 8 Main handle Mounting tool bits Warning before do it make sure unplug the machine 1 Pull out of the retainer 2 turning 180 clockwise or anticlockwise insert the accessory shank portion 1 into the hole on the front cover 2 Turning the retainer back into original position 3 Assembly ...

Page 10: ...ating Switch ON Push to the top as arrow 1 direction Push back to max as arrow 2 direction power source on then push as arrow 1 direction to max lock switch Switch OFF When press the switch button again switch is to off positon Operation 1 Pull the trigger switch after applying the tip of the bit to crushing position In some cases it s necessary to punch the tip of the bit against the crushing pos...

Page 11: ... is used after a long idle time this demolition hammer should be kept running for above 5 minutes to warm up GREASE AND OIL FILLING Warning Pull plug from power before any operations Demolition hammer mechanical part is easy to get worn and lose impact energy if without enough lubrication recommend filling grease and oil after 6 months usage The steps as follows 图 1 图 2 图 3 图 4 图 5 图 6 图 7 图 8 5 M...

Page 12: ... and Fig 6 6 Fill the 12 g oil in the cylinder please make sure it is clean before filling See Fig 7 7 Assemble back See Fig 8 a Assemble the piston into cylinder please make sure if the O ring has been assembled b Assemble the cylinder into aluminum head c Tighten the 4 inner HEX head screws be careful of no missing spring washer If tighten the screws by electrical or pneumatic driver please chec...

Page 13: ...on brush just dismantle parts as order1 2 3 after that assembly in reverse order Remark after carbon brush replacement please make sure all of the screws are tightened enough 6 Cleaning Clean the machine regularly with a soft cloth preferably after each use Solvent such as gasoline thinner alcohol etc These kind of chemical materials are not allowed to use water or soap are recommended 7 Warranty ...

Page 14: ...ation will lose its validity Machine Description Demolition Hammer Machine Type XP G65BH rated voltage power 220 240V 50Hz 2000W Applicable EC Directives EC Machinery Directive 2006 42 EC EC Low voltage directive 2006 95 EC EC Directive of Electromagnetic Compatibility 2004 108 EC Noise Directive 2000 14 EC amended by 2005 88 EC Applicable Harmonized Standards EN 60745 1 2009 A11 EN 60745 2 6 2010...

Page 15: ...15 ...

Page 16: ...16 ...

Reviews: