22
E n d o f
c a b l e
(2) Greasy and humid occasions
It is recommended to select cable with aviation plug as connector instead of AMP interface
cable.
It is necessary to make corresponding protection (glass glue/insulating cloth binding, etc.) for
the used AMP interface cable on site.
Use special cable.
(3) Interference, high current / high power occasions (such as welding equipment)
The motor is properly grounded.
High current equipment shall be grounded separately.
Reasonable wiring. Such as separation of strong and weak current cables.
Use metal shielding layer to shield, add magnetic ring to the encoder cable to resist
interference.
(4) Low / high temperature
Select cables (special cables) that meet the use conditions.
2.3.2 Xinje cable specification
1. Material composition of Xinje cable
Cross section of cable (encoder, power cable), corresponding introduction of wire skin material, wire
diameter, wire core material shielding material, etc.