3
1.1.3 Performance specifications
Servo unit
DS5 series servo drive
Applicable encoder
Standard: 17-bit/23-bit communication encoder
Input power supply
DS5□-2□P□-PTA: Single/three phases AC200-240V, 50/60Hz
Single phase AC200-240V 50/60Hz is used below 1.5KW (excluding
1.5KW)
;
It is recommended to use three-phase AC200-240V 50/60Hz when the
value is above 1.5KW (including 1.5KW).
(For the single-phase power supply, please connect to L1 and L3,
otherwise the power failure will affect the memory of parameters.)
DS5□-4□P□-PTA: three-phase AC340
~
420V, 50/60Hz
Control mode
Three-phase full-wave rectifier IPM PWM control sinusoidal current
drive mode
Using
condition
Using
temperature
-10
~
+40
℃
Storage
temperature
-20
~
+60
℃
Environment
humidity
Below 90
%
RH (no condensation)
Vibration
resistance
4.9m/s
2
Structure
Pedestal installation