12
Function
code
Description
Function
code
Description
F0.00
Driver serial number
F0.01
Type
F0.02
Data of production: year
F0.03
Data of production: month, day
F0.04
Data of production: day
F0.05
Software version
F0.06
Hardware version
4-4-2
.
Alarm information
Under auxiliary function status, set group number 1 to check alarm information.
The following are the steps:
1. Press STA|ESC to select auxiliary function status.
2. Press INC/DEC, set group number 1, short press ENTER to confirm.
3. Press INC, DEC or ENTER to change information code.
4. Press ENTER, you can see the corresponding alarm information.
Function
code
Content
unit
Modbus
address
F1.00
Current alarm code
※
1
0x0305
F1.01
Current warning code
※
2
0x0306
F1.02
Alarm/warning code 1 when alarming
0x0307
F1.03
U phase current when alarming
A
0x0308
F1.04
V phase current when alarming
A
0x0309
F1.05
Effective current when alarming
A
0x030A
F1.06
DC busbar voltage when alarming
V
0x030B
F1.07
Module temperature
℃
0x030C
F1.08
Motor speed when alarming
rpm
0x030D
F1.09
Alarm/warning code 2 when alarming
0x030E
F1.10
Alarm/warning code 3 when alarming
0x030F
F1.11
Alarm/warning code 4 when alarming
0x0310
F1.12
Alarm/warning code 5 when alarming
0x0311
F1.13
Alarm/warning code 6 when alarming
0x0312
F1.14
Alarm/warning code 7 when alarming
0x0313
※
1: when F1.00
=
0, no alarm status.
※
2: when F1.01
=
0, no warning status.
4-4-3
.
Recover to factory parameters
Operation Steps:
1. Press STA|ESC to enter auxiliary function status.
2. Press INC or DEC and set the group number 2, and short press ENTER to
confirm.
3. Long press ENTER, ‘0’ will be displayed and shine.
4. Set value 1, and long press ENTER to confirm.
5. Power on again, all parameters will recover to factory value.