Getting Started With the MultiLINX™ Cable
XAPP168 (v1.1) February 8, 2000
11
1-800-255-7778
R
MultiLINX
Operating
Characteristics
Revision
History
Table 4: Recommended Operating Conditions
Parameter
Operating
Non-Operating
DC Voltage
2.5V to 5.0V
N/A
Maximum Applied DC
Signal Voltage per
Flying Wire
–0.5V to 5.5V
N/A
Typical Current
Requirements
300mA @ 5.0V,
500mA @ 3.3V,
750mA @ 2.5V
N/A
Power Req.
2 Watts Max.
N/A
Temp. Range
0
°
C to 55
°
C
–
40
°
C
to 85
°
C
Altitude
–100 to 15000 ft
–1000 to 50000 ft
Table 5: Reliability Characteristics
Parameter
Operating
Non-Operating
Relative Humidity
5% to 90% (non-condensing at 40
°
C
)
5% to 95% (noncondensing at 65
°
C
)
Vibration
0.5mm (pp), 5 - 55 Hz
1.5mm (pp), 5 - 55 Hz
Shock
5.0G, 11 ms, 1/2 sine
30G, 11 ms, 1/2 sine
Bench Drop
Three foot drop onto a solid surface with no
physical damage
Three foot drop onto a solid surface with no physical
damage
Notes:
Each of MultiLINX Cable’s Flying wires is capable of driving a total capacitive load of 100 pF; Each of MultiLINX Cable’s Flying
wires is capable of driving a total pull-up resistance of 500 ohms; Each of MultiLINX Cable’s Flying wires is capable of driving
a total pull-down resistance of 5000 ohms.
Date
Version
Revision
10/6/99
1.0
Initial Xilinx release.
2/8/00
1.1
Updated format and Figure 1.