Setting up the battery
Description of parameters(continuation)
Parameter
Description
Cell overvoltage
Voltage above which at least one parallel is exceeded for a time determined
by the “Cell overvoltage delay” parameter, charging is disabled until the
voltage drops to the value
[Cell overvoltage - Cell overvoltage hysteresis].
Cell overvoltage delay
Time after which the overvoltage protection of the parallel is activated.
Cell overvoltage hysteresis
Hysteresis, which is responsible for how much the parallel voltage should fall
after the overvoltage protection is activated, so that the charge is enabled.
Cell undervoltage
Voltage, at which the voltage of at least one parallel is dropped for a time
determined by the “Cell undervoltage delay” parameter, the discharge is
disabled until the voltage rises to [Cell underv Cell undervoltage
hysteresis].
Cell undervoltage delay
Time after which protection against undervoltage of the parallel is activated.
Cell undervoltage hysteresis
Hysteresis, which is responsible for how much the parallel voltage should
increase after the protection against undervoltage is triggered, so that the
discharge is enabled.
Balancing mode
Three balancing options:
Always - always balance cells, except when their voltage is lower than the
value defined by the “Lowest voltage to balance” parameter.
Charge & Overvoltage - balance cells during charging or when exceeding the
maximum voltage in at least one cell.
Never - never balance cells.
BMS shutdown undervoltage
The voltage, when the voltage drops to at least one parallel for 30 seconds,
the BMS turns off completely, stopping consuming battery current. This is
necessary in case the scooter is left discharged for a long period so that
BMS does not overdischarge the battery pack by its own current
consumption.
Lowest voltage to balance
The minimum parallel voltage at which it will be balanced.
Cells disbalance threshold
How much should the parallel voltage exceed the voltage of the most
discharged parallel in order for balancing to begin.
Recuperation disable cell
voltage
If at least one parallel the voltage is higher than this value, a signal is sent to
the controller to disable the recuperation.
(continued on the next page)
12