For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the
.
Figure 5-27
Positions of PSUs
NO TE
● When 900 W AC Titanium PSUs are configured, if the input voltage ranges from 100 V AC
to 127 V AC, the output power decreases to 550 W.
● When 2000 W AC Platinum PSUs are configured, if the input voltage ranges from 200 V
AC to 220 V AC, the output power decreases to 1800 W.
● When 3000 W AC Titanium PSUs are configured:
●
If the input voltage ranges from 100 V AC to 127 V AC, the output power decreases to
1300 W.
●
If the input voltage ranges from 200 V AC to 220 V AC, the output power decreases to
2500 W.
●
If the input voltage ranges from 220 V AC to 230 V AC, the output power decreases to
2900 W.
5.9 Fan Modules
●
Supports six fan modules.
●
Supports hot swap.
●
Supports N+1 redundancy. The server runs properly when one fan fails.
●
Supports intelligent fan speed adjustment.
●
Fan modules of the same part number (P/N code) must be used in a server.
FusionServer 2488H V7 Server
Technical White Paper
5 Hardware Description
Issue 01 (2023-09-01)
Copyright © xFusion Digital Technologies Co., Ltd.
43