PMem module Error Detection and Correction
●
PMem module Device Failure Recovery (SDDC)
●
PMem module Package Sparing (DDDC)
●
PMem module Patrol Scrubbing
●
PMem module Address Error Detection
●
PMem module Data Poisoning (Corrupt Data Containment)
●
PMem module Viral
●
PMem module Address Range Scrub (ARS)
●
PMem module Error Injection
●
DDR-T Command and Address Parity Check and Retry
●
DDR-T Read Write Data ECC Check and Retry
●
PMem module Faulty DIMM Isolation
●
PMem module Error Reporting
5.5 Storage
5.5.1 Drive Configurations
Table 5-9
Drive configuration
Configuration
Front Drive
Rear Drive
Drive
Management
Mode
4 x 3.5" drive
pass-through
configuration 1
● Front drive: 4 x
3.5
– Slots 0 to 3
support only
SATA drives.
-
● PCH
4 x 3.5" drive
pass-through
configuration 2
● Front drive: 4 x
3.5
– Slots 0 to 3
support only
SAS/SATA
drives.
● I/O module 1: 2
x 2.5"
– Slots 12 and
13 support
only SAS/
SATA drives.
● 1 x screw-in
RAID controller
card
4 x 3.5" drive
pass-through
configuration 3
● Front drive: 4 x
3.5
– Slots 0 to 3
support only
SAS/SATA
drives.
-
● 1 x PCIe RAID
controller card
FusionServer 1288H V6 Server
Technical White Paper
5 Hardware Description
Issue 10 (2023-04-30)
Copyright © xFusion Digital Technologies Co., Ltd.
36