FusionServer 1288H V6 Server
Technical White Paper
2 Features
2022-06-25
9
⚫
Flexible drive configurations meet a variety of business requirements and ensure high
elasticity and scalability of storage resources.
⚫
The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100 times
more I/O operations per second (IOPS) than a typical hard disk drive (HDD). The use of
all SSDs provides higher I/O performance than the use of all HDDs or a combination of
HDDs and SSDs.
⚫
The use of 12 Gbit/s SCSI (SAS) serial connection for internal storage provides 2x data
transmission rate than the use of 6 Gbit/s SAS connection, maximizing the performance
of I/O-intensive applications.
⚫
With Intel integrated I/O, the third-generation Intel
®
Xeon
®
Scalable processors integrate
the PCIe 4.0 controller to shorten I/O latency and improve overall system performance.
⚫
The server supports a maximum of three PCIe 4.0 expansion slots
⚫
The server supports two FlexIO cards (applicable to the OCP 3.0 network adapter) with
flexible configuration of GE/10GE/25GE/100GE network adapters, which are hot
swappable.
Availability and Serviceability
⚫
Carrier-class components with process expertise ensure high system reliability and
availability.
⚫
The server supports hot-swappable SAS/SATA/NVMe drives. SAS/SATA drives support
RAID 0, 1, 1E, 10, 5, 50, 6, and 60, depending on the RAID controller card used. It also
uses a supercapacitor to protect the RAID cache data against power failures.
⚫
SSDs offer better reliability than HDDs, prolonging system uptime.
⚫
The server provides simplified O&M and efficient troubleshooting through the UID/HLY
indicators on the front panel, fault diagnosis LED, and iBMC WebUI.
⚫
The panel provides iBMC direct connect management ports to support local iBMC O&M,
improving O&M efficiency.
⚫
A server provides two hot-swappable PSUs in 1+1 redundancy mode and seven
hot-swappable fan modules in N+1 redundancy mode, improving system availability.
⚫
The built-in iBMC monitors system parameters in real time, triggers alarms, and
performs recovery actions to minimize the system downtime.
⚫
For details about the warranty policy, visit
Manageability and Security
⚫
The built-in iBMC monitors server operating status and provides remote management.
⚫
A password is required for accessing the BIOS, ensuring system boot and management
security.
⚫
The NC-SI feature allows a network port to serve as a management port and a service
port. The NC-SI feature is disabled by default and can be enabled through the iBMC or
BIOS.
⚫
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault handling.
⚫
The server chassis panel ensures security of local data.
⚫
Chassis cover opening detection is supported to enhance security.
⚫
Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer
overflow attacks when working with a supported OS.