08/2012
6-69
WorkCentre 5021/5019
6.3.16
General Procedures
Initial Issue
6.3.16 NVM SYSTEM
Table 1 NVM SYSTEM
Chain-Link
NVM Name
Tools
P#
Setting
Range
(Minimum
Value)
Setting
Range
(Maximum
Value)
Default
Value
Write
Allowed/
Protected
Default
Value
Yes/No
Description
610-400
KO_PASSWORD_1
400
0
9
1
O
O
The 1st digit (highest order digit) number of the KO Password.
610-401
KO_PASSWORD_2
401
0
9
1
O
O
The 2nd digit number of the KO Password.
610-402
KO_PASSWORD_3
402
0
9
1
O
O
The 3rd digit number of the KO Password.
610-403
KO_PASSWORD_4
403
0
9
1
O
O
The 4th digit number of the KO Password.
610-404
KO_PASSWORD_5
404
0
10
1
O
O
The 5th digit number of the KO Password. '10' indicates a termina-
tion.
610-405
KO_PASSWORD_6
405
0
10
10
O
O
The 6th digit number of the KO Password. '10' indicates a termina-
tion.
610-406
KO_PASSWORD_7
-
10
10
10
O
O
The 7th digit number of the KO Password. '10' indicates a termina-
tion.
610-407
KO_PASSWORD_8
-
10
10
10
O
O
The 8th digit number of the KO Password. '10' indicates a termina-
tion.
610-408
KO_PASSWORD_9
-
10
10
10
O
O
The 9th digit number of the KO Password. '10' indicates a termina-
tion.
610-409
KO_PASSWORD_10
-
10
10
10
O
O
The 10th digit number of the KO Password. '10' indicates a termina-
tion.
610-410
KO_PASSWORD_11
-
10
10
10
O
O
The 11th digit number of the KO Password. '10' indicates a termina-
tion.
610-411
KO_PASSWORD_12
-
10
10
10
O
O
The 12th digit (lowest order digit) number of the KO Password.'10'
indicates a termination.
620-407
CHINESE_PAPER
205
0
0
0
O
O
0: GCO Size
621-400
NVM_MATCHING
-
0
2
0
O
X
0: Default Value
1: Perform restore from Controller NVM to Backup NVM
2: Perform restore from Backup NVM to Controller NVM
700-120
TIMEZONE
8
0
32
7
O
O
0: UTC -12:00, 1: UTC -11:00, 2: UTC -10:00
3: UTC -09:00, 4: UTC -08:00, 5: UTC -07:00
6: UTC -06:00, 7: UTC -05:00, 8: UTC -04:00
9: UTC -03:30, 10: UTC -03:00, 11: UTC -02:00
12: UTC -01:00, 13: UTC 00:00, 14: UTC +01:00
15: UTC +02:00, 16: UTC +03:00, 17: UTC +03:30
18: UTC +04:00, 19: UTC +04:30, 20: UTC +05:00
21: UTC +05:30, 22: UTC +05:45, 23: UTC +06:00
24: UTC +06:30, 25: UTC +07:00, 26: UTC +08:00
27: UTC +09:00, 28: UTC +09:30, 29: UTC +10:00
30: UTC +11:00, 31: UTC +12:00, 32: UTC +13:00
700-122
DATE_FORMAT
6
0
2
0
O
O
0: YYMMDD
1: MMDDYY
2: DDMMYY
700-123
TIME_FORMAT
7
0
1
1
O
O
0: 12h
1: 24h
Summary of Contents for WorkCentre 5019
Page 17: ...08 2012 2 6 WorkCentre 5021 5019 2 1 3 Initial Issue Status Indicator RAPs ...
Page 19: ...08 2012 2 8 WorkCentre 5021 5019 2 2 1 1 Initial Issue Status Indicator RAPs ...
Page 21: ...08 2012 2 10 WorkCentre 5021 5019 003 500 795 003 951 Initial Issue Status Indicator RAPs ...
Page 23: ...08 2012 2 12 WorkCentre 5021 5019 004 345 Initial Issue Status Indicator RAPs ...
Page 33: ...08 2012 2 22 WorkCentre 5021 5019 023 600 Initial Issue Status Indicator RAPs ...
Page 37: ...08 2012 2 26 WorkCentre 5021 5019 041 210 211 Initial Issue Status Indicator RAPs ...
Page 39: ...08 2012 2 28 WorkCentre 5021 5019 042 325 614 Initial Issue Status Indicator RAPs ...
Page 41: ...08 2012 2 30 WorkCentre 5021 5019 045 310 045 313 Initial Issue Status Indicator RAPs ...
Page 43: ...08 2012 2 32 WorkCentre 5021 5019 061 321 061 325 Initial Issue Status Indicator RAPs ...
Page 47: ...08 2012 2 36 WorkCentre 5021 5019 071 105 Initial Issue Status Indicator RAPs ...
Page 51: ...08 2012 2 40 WorkCentre 5021 5019 075 135 Initial Issue Status Indicator RAPs ...
Page 57: ...08 2012 2 46 WorkCentre 5021 5019 092 660 668 092 910 Initial Issue Status Indicator RAPs ...
Page 59: ...08 2012 2 48 WorkCentre 5021 5019 093 312 093 912 Initial Issue Status Indicator RAPs ...
Page 61: ...08 2012 2 50 WorkCentre 5021 5019 095 910 Initial Issue Status Indicator RAPs ...
Page 63: ...08 2012 2 52 WorkCentre 5021 5019 116 321 116 377 Initial Issue Status Indicator RAPs ...
Page 65: ...08 2012 2 54 WorkCentre 5021 5019 117 326 Initial Issue Status Indicator RAPs ...
Page 67: ...08 2012 2 56 WorkCentre 5021 5019 123 314 Initial Issue Status Indicator RAPs ...
Page 75: ...08 2012 2 64 WorkCentre 5021 5019 2 2 4 8 Initial Issue Status Indicator RAPs ...
Page 89: ...08 2012 3 14 WorkCentre 5021 5019 IQ15 Initial Issue Image Quality ...
Page 106: ...08 2012 4 4 WorkCentre 5021 5019 4 1 Initial Issue Disassembly Assembly and Adjustment ...
Page 116: ...08 2012 4 14 WorkCentre 5021 5019 REP 1 6 1 Initial Issue Repairs and Adjustments ...
Page 118: ...08 2012 4 16 WorkCentre 5021 5019 REP 2 1 1 Initial Issue Repairs and Adjustments ...
Page 122: ...08 2012 4 20 WorkCentre 5021 5019 REP 4 1 1 Initial Issue Repairs and Adjustments ...
Page 124: ...08 2012 4 22 WorkCentre 5021 5019 REP 6 1 1 Initial Issue Repairs and Adjustments ...
Page 126: ...08 2012 4 24 WorkCentre 5021 5019 REP 7 1 1 Initial Issue Repairs and Adjustments ...
Page 130: ...08 2012 4 28 WorkCentre 5021 5019 REP 8 2 1 REP 8 2 2 Initial Issue Repairs and Adjustments ...
Page 162: ...08 2012 4 60 WorkCentre 5021 5019 REP 19 2 1 Initial Issue Repairs and Adjustments ...
Page 190: ...08 2012 4 88 WorkCentre 5021 5019 ADJ 1 3 2 Initial Issue Repairs and Adjustments ...
Page 192: ...08 2012 4 90 WorkCentre 5021 5019 ADJ 8 1 1 Initial Issue Repairs and Adjustments ...
Page 198: ...08 2012 4 96 WorkCentre 5021 5019 ADJ 18 2 2 Initial Issue Repairs and Adjustments ...
Page 209: ...08 2012 5 6 WorkCentre 5021 5019 5 1 4 5 1 5 Initial Issue Parts List ...
Page 267: ...08 2012 5 64 WorkCentre 5021 5019 99 8 Initial Issue Parts List ...
Page 293: ...08 2012 6 24 WorkCentre 5021 5019 6 1 28 6 1 29 Initial Issue General Procedures ...
Page 295: ...08 2012 6 26 WorkCentre 5021 5019 6 2 1 6 2 2 Initial Issue General Procedures ...
Page 299: ...08 2012 6 30 WorkCentre 5021 5019 6 3 1 3 Initial Issue General Procedures ...
Page 303: ...08 2012 6 34 WorkCentre 5021 5019 6 3 2 3 Initial Issue General Procedures ...
Page 305: ...08 2012 6 36 WorkCentre 5021 5019 6 3 3 Initial Issue General Procedures ...
Page 317: ...08 2012 6 48 WorkCentre 5021 5019 6 3 6 Initial Issue General Procedures ...
Page 319: ...08 2012 6 50 WorkCentre 5021 5019 6 3 7 Initial Issue General Procedures ...
Page 325: ...08 2012 6 56 WorkCentre 5021 5019 6 3 10 Initial Issue General Procedures ...
Page 327: ...08 2012 6 58 WorkCentre 5021 5019 6 3 11 Initial Issue General Procedures ...
Page 331: ...08 2012 6 62 WorkCentre 5021 5019 6 3 13 Initial Issue General Procedures ...
Page 335: ...08 2012 6 66 WorkCentre 5021 5019 6 3 14 Initial Issue General Procedures ...
Page 337: ...08 2012 6 68 WorkCentre 5021 5019 6 3 15 Initial Issue General Procedures ...
Page 347: ...08 2012 6 78 WorkCentre 5021 5019 6 3 17 Initial Issue General Procedures ...
Page 353: ...08 2012 6 84 WorkCentre 5021 5019 6 3 19 Initial Issue General Procedures ...
Page 355: ...08 2012 6 86 WorkCentre 5021 5019 6 3 20 Initial Issue General Procedures ...
Page 358: ...08 2012 6 89 WorkCentre 5021 5019 6 4 1 3 General Procedures Initial Issue ...
Page 359: ...08 2012 6 90 WorkCentre 5021 5019 6 4 1 3 Initial Issue General Procedures ...
Page 377: ...08 2012 6 108 WorkCentre 5021 5019 6 4 3 Initial Issue General Procedures ...
Page 393: ...08 2012 7 10 WorkCentre 5021 5019 7 1 2 Initial Issue Wiring Data ...
Page 415: ...08 2012 7 32 WorkCentre 5021 5019 4 5 Initial Issue Wiring Data ...
Page 423: ...08 2012 7 40 WorkCentre 5021 5019 CH2 1 Initial Issue Wiring Data ...
Page 427: ...08 2012 7 44 WorkCentre 5021 5019 CH3 3 Initial Issue Wiring Data ...
Page 429: ...08 2012 7 46 WorkCentre 5021 5019 CH4 1 Initial Issue Wiring Data ...
Page 437: ...08 2012 7 54 WorkCentre 5021 5019 CH5 7 Initial Issue Wiring Data ...