April 2017
2-541
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
117-347, 349, 350, 117-348
Status Indicator RAPs
Launch Issue
117-347, 349, 350 Service Fail RAP
117-347 When the SEEP extension billing counter have been used and billing count cannot be
performed as new extension counter cannot be obtained.
117-349 Detects this fail when enters a state where it is unable to continue operating as GRS.
117-350 A problem has occurred in the AirPrint scan service software processing and it is
unable to continue with the subsequent processes.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
3.
Reload the software,
GP 4
.
4.
Perform the
OF2
Special Boot Modes RAP.
117-348 Uninitialized Used SD Card RAP
117-348 An un-initialized SD card that had been used in another machine was recognized.
Procedure
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Initialize the NVM, perform
dC301
NVM Initialization.
3.
Ensure that all connectors on the drive PWB,
PL 1.10 Item 3
and the ESS PWB,
PL 3.10
Item 6
are securely connected. Ensure all surface mounted modules on both PWBs are
securely connected.
4.
Reload the software,
GP 4
.
5.
If the fault persists, install a new ESS PWB,
PL 3.10 Item 6
.