April 2017
2-445
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer
041-340, 041-341, 041-371
Status Indicator RAPs
Launch Issue
041-340, 041-341 Drive PWB NVM (EEPROM) Fail RAP
BSD-ON:
BSD 3.1 PWB Communications (ESS PWB to Drive PWB)
041-340 NVM (EEPROM) data abnormality.
041-341 NVM (EEPROM) access error.
Initial Actions
WARNING
Ensure that the electricity to the machine is switched off while performing tasks that do
not need electricity. Refer to
GP 10
. Disconnect the power cord. Electricity can cause
death or injury. Moving parts can cause injury.
Fault code 041-340 Only. Enter
dC131
. Check that the NVM values that follow are set to 0:
•
740-016 Range Over Chain No
•
740-017 Range Over Link No
•
740-018 Range Over Chain Link
•
740-019 Range Over Value
•
740-020 Write in Progress Range Over Chain No
•
740-021 Write in Progress Range Over Link No
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
Reload the software,
GP 4
.
3.
dC301
NVM Initialization.
4.
If the fault persists, install new components as necessary:
•
Drive PWB,
PL 1.10 Item 3
.
•
ESS PWB,
PL 3.10 Item 6
.
041-371 Productivity Not Set RAP
041-371 Productivity not set.
Procedure
Perform the steps that follow:
1.
Switch off, then switch on the machine,
GP 10
.
2.
If the fault persists, perform
dC132
.