UNINET IMAGING INC.
•
XEROX
®
PHASER 6250 CARTRIDGE REMANUFACTURING INSTRUCTIONS
11. Wipe the seal opening and surroundings clean using iso-
propyl alcohol and a lint free cloth.
INSTALLING THE CLEARSEAL
®
ADHESIVE
12. Make sure that the new seal is being placed in its proper
position (shown) before applying.
NOTE
: Optional UniNet Clear Seal
®
universal adhesive for use in
Xerox Phaser
®
6200, 6250, OEM BK/C/M/Y toner cartridges
(UniNet part #10354).
13. Remove the adhesive backing of the Clearseal
®
and careful-
ly place over the opening as shown.
Apply pressure using your fingers to ensure a tight seal.
14. gently wrap the seal flap around the toner fill opening (as
shown) while you prepare to insert the cartridge.
This will ensure that the seal flap properly exits the opposite end
of the container.