Phaser 6115MFP Multifunction Product Service Manual
3-15
Error Codes and Messages
0CH Power Supply Cooling Fan Malfunction
Power Supply cooling fan motor inoperative, noisy, or erratic.
Applicable Status Code
0CH:
Power Supply Cooling Fan Motor Malfunction
Initial Actions
■
Check power cord and connections.
■
Power down and reboot the system.
Warning
To avoid the potential of electric shock, ensure the power to the printer is
off and the power cord is disconnected from the wall outlet prior to
performing each step of the following troubleshooting procedure.
2
Check the Engine Control Board
connector P/J4.
Is the connector seated properly.
Go to Step 4.
Reseat the
connector. If
the problem
persists, go to
Step 4.
3
Check the operation of the Ventilation
Fan motor.
Is the motor faulty?
Replace the
motor
(page 8-96). If
the problem
persists, go to
Step 5.
Go to Step 5.
4
Replace the Engine Control Board
(page 8-57).
Does the problem persist?
Go to Step 6.
Complete.
5
Replace the DC Power Supply 1
(page 8-60).
Complete
Troubleshooting Reference Table
Applicable Parts
Wiring and Plug/Jack References
■
Power Supply Cooling Fan
Motor, PL4.8.1
■
Engine Control Board,
PL4.19.15
■
DC Power Supply 1, PL4.19.3
■
Print Engine Board Plug/Jack Designators
■
Engine Control Board to Motor Wiring
■
Engine Control Board to DC Power Wiring
Troubleshooting Procedure Table (Continued)
Step
Action and Questions
Yes
No
Summary of Contents for Phaser 6115 MFP
Page 1: ...Service Manual Phaser 6115MFP 701P28980 Color Laser Multifunction Product...
Page 2: ......
Page 44: ...1 22 Phaser 6115MFP Multifunction Product Service Manual General Information...
Page 144: ...3 42 Phaser 6115MFP Multifunction Product Service Manual Error Codes and Messages...
Page 270: ...7 16 Phaser 6115MFP Multifunction Product Service Manual Cleaning and Maintenance...
Page 530: ......
Page 531: ......
Page 532: ...701P28980...