72
I-Class
Advanced Entry Calibration (continued)
Step
Operator Action
Displayed Message
Comment
6
Press the
Key
to scroll to ‘Advanced
Entry’.
You are entering
Advanced Entry
Calibration.
7
Press the
Key.
Press the
Key to abort this
procedure.
8
Press the
Key.
You are beginning
the Advanced
Entry Calibration.
9
Press the
Key.
Place the label under the
Sensor Eye Mark and
lower the printhead
assembly.
-OR-
If using preprinted
media, ensure the
label area under
the sensor is free
of preprinted text,
graphics or
borders.
10
Press the Key
to select the setting
(denoted by an ‘*’) and
then record the sensor
reading (the ‘yyy’ value)
in a table similar to the
one shown after Step 12,
as a
Label Value
.
Next, press the
Key to increment the
Gain Number.
Repeat this step for each
of the Gain Numbers
(00-32).
-OR-
Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.
þ
Note:
Never
position the
sensor over a
perforation when
recording a
sensor reading.