9
Manual Feed
Manual feed media source will be ignored when used with the Accxes Client Tools’ page composition
feature
Go to Accxes Client Tools > Job Option tab > Composition tab > Select Overlay Images > Media Source drop down
menu. Although “Manual Feed” is listed as a choice of media source for page composition jobs, the print job will
be treated as if AUTO media source was selected. If an appropriate roll of media is available, it will be printed on
that media; otherwise, the job will query until the correct roll media is installed. In addition, other Media Source
selections will be treated as AUTO if an appropriate roll of media is available in a different roll.
InstantAccxes
When using InstantAccxes folders on an IPv6 network you must reference the system directly as shown below:
Vista: Start>Run> \\<Controller Name>
Linux: smb://<Controller Name>
InstantAccxes Folders not accessible from MAC on IPv6
InstantAccxes folders are not accessible to systems running MAC OS 10.4 or earlier versions on IPv6 networks.
Web Printer Management Tool
Printer Queue – Main Web Printer Management Tool Screen
The FreeFlow Accxes Controller supports a maximum of 120 active printer jobs in the queue and 8 active copy
jobs. If subsequent jobs are sent before the 128th prints, ports will refuse connections and there can be scan
errors; when there are fewer jobs in the queue, the jobs can then be resubmitted or scanned. Additionally,
completed jobs will be removed from the queue display immediately to make room for the newly submitted print
jobs. To avoid these issues, keep the number of active print jobs to under the 128 limit.
NOTE: More than 128 files can be sent from the Document Submit Tool as one print job, but all of the files in the print job must
have printed before sending subsequent jobs, or the jobs will be refused
German users only
Zum Drucken von Etiketten mit Umlauten DRUCKERVORGABEN > DRUCKER-EINSTELLUNG > Plot-Etiketten
wählen. Anschließend im Dropdown-Menü für Fonts einen der folgenden Fonts wählen: HP2 Stick Font Latin - 1
oder HP2 Stick font Latin - 1 – Proportional.
Large Scaling Factors
Images set to scale beyond the largest installed roll will not scale beyond the largest width unless a specific roll is
selected, a specific page size is selected, or mismatch mode is set to something other than scaling. This is a
behavior that has changed from previous releases (prior to 9.0).
For example: The largest roll installed is 36". Scaling is set to 999%. Submit an ARCH E sized drawing (Media Size
= Any, Mismatch = Scaling). The drawing will not be scaled.
In order for the output to exhibit the desired scaling factor, one of the following conditions must be met:
What to do:
•
Set Mismatch Mode to Substitute
•
Request a Media Size of ARCH E via Web Printer Management Tool, ACT, or the Driver
•
Request a Media Size 36" Roll via Web Printer Management Tool, ACT, or the Driver