The main DocuTech 180 HLC components are: 

 

• 

Digital Front End Controller 

• 

CD/DVD combo drive 

• 

color flat panel monitor 

• 

keyboard and mouse 

• 

Ethernet interface (10/100/1000 BaseT) 

• 

Two printer interface cards 

• 

Controller Stand 

• 

Options 

• 

USB floppy disk drive 

• 

Solaris 10 and DocuSP print services software 
 

• 

Printer 

• 

Black plus one highlight color* 

• 

Xerographic engine with laser raster imaging system for 
black and Light Emitting Diode for color 

• 

Permanent housing for black dry ink; customer changeable 
unit (CCU) for color dry ink 

• 

Prints simplex or duplex 

• 

Two-tray interposer 

• 

In-line finishing module which includes a binder, stitcher, 
and stacker 

• 

Optional Bypass Transport to provide connection to 
additional finishers 

* Additional dry inks, not listed on this document, will be customer 
options as they become available, and will be offered under standard 
Xerox terms and conditions. 
 

Space Requirements / Service Space Envelope  

The dimensions shown below are absolute minimums. 
 

Configuration 

Width 

Depth 

Min total 

req’d 

Width x 

depth 

Weight 

With two tray 
Interposer and 
Binder/Stitcher 

78 (in) 

198 

(cm) 

42 (in) 

106.6 

(cm) 

293.1 x 

142.0 (in) 

744.5 x 

360.6 

(cm) 

3724 

(lbs) 

1689 
(kgs) 

Controller stand 

36 (in) 

91 (cm) 

36 (in) 

91 (cm) 

 

 

 

• 

The minimum total space required includes the required space 
necessary for the Xerox service personnel to service the printer. 

• 

A minimum of 78 inches/198 cm clearance from the floor to the 
nearest overhead obstruction must be maintained. 

• 

No obstructions, such as power poles, are allowed such that 
they interfere with the Xerox Service Representative’s ability to 
access the rear of the printer for service. 

• 

The printing system must be installed in a fixed location. 

• 

Space requirements for the controller stand are 36 x 36 
inches/91 x 91 cm. 

• 

For proper operation, the printer must be perfectly level.  On 
floors less than two degrees out of level, a leveling kit must be 
used to level the equipment.  The printer will not function 
properly on floors more than two degrees out of level. 

• 

For detailed space requirements and diagrams, refer to the 
DocuTech 128/155/180 HighLight Color Installation Planning 
Guide. 

Electrical Requirements (printer)

 

The printer requires for 60 HZ service (2 cords required): 

 

 

MultiSource 

2-phase, dual power cord 

configuration 

Voltage 208/240

(4 wire)

 208/240 

(4 wire)

 

Amperage (dedicated) 

50 

30 

Cycles 

60 Hz 

60 Hz 

Receptacle Xerox Part No. 

 

 

Receptacle NEMA Part No. 

14-50R 

14-30R 

Receptacle Diagram 

 

 

Power Cord Kit Number 

 

 

Power Cord Length 

15 feet 

15 feet 

 

For 50 Hz service: 

• 

30 amp dedicated service (WYE): 220/380 VAC or 230/400 
VAC or 240/415 VAC (3 phase) 

Agency certifications: UL, cUL, CE Mark, FCC 

Electrical Requirements (Controller) 

The Controller requires 20 AMP dedicated service. The information 
for the 20 Amp electrical service is identified below. 

 

 

Controller 

36 Track Tape 

(Optional) 

Line Options 

Dedicated 

Dedicated 

Voltage 115vac 

115vac 

Amperage 20 

20 

Cycles 

60 Hz 

60 Hz 

Xerox Receptacle Part No. 

600S3703 

600S3703 

Receptacle NEMA Part No. 

5-20R 

5-20R 

Power Cord Xerox Part No. 

98K19950 

98K19950 

Receptacle Diagram 

 

 

 97S02370 

97S02370 

Installation Considerations 

 

1. 

Dedicated electrical service is required for each component. 

2. 

The controller can be connected to a 15 amp or 20 amp outlet. 

3. 

The length of the cable from the controller to the printer is 16 
feet (4.8 metres). 

4. 

Do not use an adapter to connect the controller to an electrical 
outlet that lacks a ground connection terminal. 

5. 

The customer is responsible for providing the network and the 
client workstation(s).  The Ethernet interface on the DocuSP 
controller is a auto-sensing 10/100/1000 - MB/sec twisted pair 
standard (BaseT). 

6. 

The Ethernet connection to the DocuSP controller must be 
compatible with the Institute of Electrical and Electronics 
Engineers (IEEE) 802.3 standard. 