Volume 1 / Print Engine - Diagnostics, Tests & NVRAM
1
-
163
Checking Lead Edge Registration
Note
NVM (Non-Volatile Memory) and NVRAM (Non-Volatile Random
Access Memory) are synonymous. NVM is displayed by the
Control Panel. NVRAM appears in documented text.
Note
Use only A4 paper or 8.5” x 11” paper and make certain the tray
being tested is the only tray installed when generating the test
print.
Checking Lead Edge Registration
1.
Generate a Registration Grid Pattern Test Print, see page 1-155 to set up and page
1-156 for specifics on Grid Pattern test print launch.
Note
The Grid Pattern test print on your printer may, or may not,
display edge lines. If no edge lines appear in your test print,
simply measure to the end of any line perpendicular to the Lead
Edge.
2.
Using a metric scale, measure the distance from the lead edge of the test sheet to the
end of any line, or the edge line. The distance should be 4.0 mm (+/- 1.5 mm in
Simplex, +/- 1.9 mm in Duplex), see illustration.
3.
If the line is /- 1.5 mm from the Lead Edge, the printer is within specification.
If it is greater than 1.5 mm, refer to line 16 in Table 1-104 “NVRAM Adjustment
Table,” beginning on page 159 (Lead Edge Registration) for adjustment information.
Note
When checking registration, it is recommended to run test prints
from all available trays and compare individual results before
making any adjustments. Doing this will help you determine
where any adjustments are required.
Adjusting Lead Edge Registration
1.
Enter Diagnostics Mode, see page 1-154.
2.
Press [1] or [5] until “NVM Lead Edge” appears in the bottom line of the display.
3.
Press [2] or [6] until the tray you wish to adjust appears in the bottom line of the
display.
4.
When prompted for a password, sequentially press [0], [7],[3], [4] to gain entry.
5.
Press [3] or [7] once to display the current numerical registration setting.
Fig 1-33 Lead Edge Registration