July 2019
2-11
Xerox® B205/B215 Multifunction Printer Service Manual
07-130 , 07-500
Status Indicator RAPs
Initial Release
Y
N
Check that all voltages are present between the HVPS PWB and the Main
PWB.
The voltages between the HVPS PWB and the Main PWB are
present.
Y
N
•
Install a new HVPS PWB,
PL 4.1 Item 2
.
•
Install a new Main PWB,
PL 1.1 Item 4
.
Install a new Paper Feed Sensor PWB,
PL 4.4 Item 20
.
Install a new Paper Feed Sensor PWB,
PL 4.4 Item 20
.
Install a new Paper Feed Sensor PWB,
PL 4.4 Item 20
.
In Diagnostics Mode, go to
[101-Clutch, Tray 1 Pick up]
to energize the clutch.
The
clutch engages.
Y
N
Check for 24VDC on the Paper Feed PWB.
The voltage is present at the connec-
tor on the Paper Feed PWB.
Y
N
Check that all voltages are present between the HVPS PWB and the Main
PWB.
The voltages between the HVPS PWB and the Main PWB are pres-
ent.
Y
N
•
Install a new HVPS PWB,
PL 4.1 Item 2
.
•
Install a new Main PWB,
PL 1.1 Item 4
.
Install a new Paper Feed PWB,
PL 4.1 Item 15
.
Install a new Feed Clutch,
PL 4.1 Item 5
.
Perform SCP Final Actions.
Remove any jammed paper. Check the following for wear or damage and replace as required:
•
Retard Roll,
PL 4.5 Item 15
.
•
Paper Feed Roll Assembly,
PL 4.5 Item 11
.
•
Earth Transfer Plate,
PL 4.4 Item 1
.
•
Earth Transfer Plate Springs,
PL 4.4 Item 3
and
PL 4.4 Item 7
.
07-500 Manual Feed Slot Paper Empty RAP
BSD-ON:
BSD 1
Control Panel Fault Displayed
B205:
Bypass Empty
B215:
Bypass Tray is Out of Paper
The Manual Feed Slot Empty Sensor failed to detect paper in the Manual Feed Slot.
Initial Actions
Ensure that paper is loaded in the tray. Clear any jammed sheets. (Refer to Section 11 in the
Xerox® B215/B205 User Guide for detailed instructions on jam clearance.)
WARNING
Do not perform repair activities with the power on or electrical power supplied to the
machine. The machine could activate and cause serious personal injury when the power
is on or electrical power is supplied.
DANGER: Ne pas effectuer de dépannage avec le contact principal activé ou avec l'ali-
mentation électrique appliquée à la machine: celle-ci pourrait démarrer et causer de
graves blessures.
AVVERTENZA: Non effettuare alcuna riparazione con la macchina accesa o con l'ali-
mentazione elettrica inserita. La macchina potrebbe avviarsi all'improvviso e causare
gravi ferite.
VORSICHT: Es dürfen keine Reparaturarbeiten durchgeführt werden, solange das Gerät
eingeschalten oder mit der Stromquelle verbunden ist. Das Gerät kann u.U in den Aktiv-
Zustand übergehen und somit erhebliche körperliche Schäden verursachen.
AVISO: No realice reparaciones con la máquina encendida o conectada a la corriente.
La máquina podría activarse y ocasionar daños personales graves.
Procedure
Check the Registration Sensor actuator.
The actuator moves freely and is undamaged.
Y
N
Install a new Registration Sensor Actuator,
PL 4.4 Item 19
.
Enter Diagnostics Mode, Select
[Machine Test, Diagnostics Mode, DC330 Component
Control, 102-Sensor, Registration Sensor}
to block and clear the Registration Sensor.
The
sensor signal changes.
Y
N
Check for 3.3VDC on the Main PWB.
The voltage is present on the Main PWB.
Y
N
•
Install a new HVPS PWB,
PL 4.1 Item 2
.
•
Install a new Main PWB,
PL 1.1 Item 4
.
Install a new Paper Feed Sensor PWB, PL
PL 4.4 Item 20
.
Perform SCP Final Actions.
A
B
C
Summary of Contents for B205
Page 1: ...Xerox B205 B215 Multifunction Printer Service Manual 702P07550 July 2019 Initial Release...
Page 3: ...0 0 00 2 No Product Name Assigned Preliminary Working Document Section Name...
Page 5: ...July 2019 ii Xerox B205 B215 Multifunction Printer Service Manual Initial Release Introduction...
Page 139: ...July 2019 5 2 Xerox B205 B215 Multifunction Printer Service Manual Initial Release Parts Lists...
Page 201: ...July 2019 7 2 Xerox B205 B215 Multifunction Printer Service Manual Initial Release Wiring Data...