Xerox 8700 MICR Product Safety Data Sheet Download Page 2

All measurements were made on products performing within established operating specifications and received
recommended maintenance procedures.  Xerox certifies that this product meets or exceeds the applicable standards for
safety and emissions.

Product:  8700 MICR

PSDS No.:  0800B

 Section V - Emission/Exposure Information*

Light Source

Laser-Class 3B System/Class 1 Product.
Light Path is internal to the printer and shielded to prevent light leakage or direct viewing.
Meets BRH requirements for operator safety.

Electromagnetic Emissions

FCC/DOC:  Class/Level A

Audible Noise

TLV

75.2 db

85 db (A)

Ozone**

TLV:

0.009 ppm

0.1 ppm

Total Dust** 

TLV

0.04 mg/m

10 mg/m

3

Selenium

TLV

Arsenic**

PEL

0.3 ug/m

3

10 ug/m

3

Tellurium

TLV

TLV

 (Threshold Limit Value) and

 PEL

 (Permissible Exposure Level) respectively set by American Conference of

Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are
considered maximum exposure permitted to ensure no health hazard.  

TWA

 (Time Weighted Average) for a

normal eight hour workday.

** Emissions data taken in a 28 m

3

 room with 1/2 room change per hour for service personnel exposure only.

Customer operator exposure level to be lower than levels noted.  Emissions data taken from the 9700 MICR
Emissions Report.

Reviews: