HPX60 User’s Manual
Xenotronix/TLI
5
MAINTENANCE INSTRUCTIONS
FUSE REPLACEMENT - The AC input module contains the main fuse and a spare fuse.
Detach the power cord. Use a flat head screwdriver or a coin to pry open the fuse drawer
or holder. Replace the blown fuse with the spare. You can use the old fuse to push out the
spare fuse. Now is a good time to install a new spare fuse. Replace fuses only with the
same type (as indicated in this manual) and value (as indicated on the charger).
CLEANING - Unplug the charger and disconnect the battery before attempting any
cleaning. If it becomes necessary to clean the enclosure, wipe the enclosure exterior with
a damp cloth. If necessary, use a mild detergent. Do not use an abrasive cleanser or spray
cleaners directly onto the charger. Do not immerse unit in water.
BATTERY CHARGER SPECIFICATIONS
General Conditions
25 °C (77 °F)
Operating temperature
0 to 34 °C (32 to 93 °F)
Storage temperature
-40 to 80 °C (-40 to 176 °F)
Dimensions
W 6.65" (16.9 cm) x D 5.3" (13.5 cm) x H 3.4" (8.6 cm)
Weight
7.4 lbs. (3.4 kg)
Input Fuse Type
5 x 20 mm fast acting, glass cartridge, UL/CSA approved
Power Requirements
115/230 VAC, 50-60 Hz, 0.98 A
Output Ratings (standard calibration):
Model
HPX60-12C400 HPX60-24C200
Charge Amps
4 A
2 A
Charge Voltage
14.40 VDC
28.8 VDC
Switch Amps
approx. 533 mA
approx. 267 mA
Float Voltage
13.60 VDC
27.20 VDC
Other Models (standard calibration):
Charge Amps
see marking label
Charge Voltage
2.40 V/Cell
Switch Amps
approx. Charge Amps/7.5
Float
Voltage
2.267
V/Cell
Safety Agency Approval:
CSA (12 V models only)