HPX10 User’s Manual
Xenotronix/TLI
2
INTRODUCTION
This unit is a two stage, constant voltage
battery charger with current limiting, current
fold back, and automatic temperature
compensation of the output voltage. It is
protected against shorting the output
terminals and reversing the output terminals
on a battery. Various output cables are
available. There is one indicator light. It
lights green to indicate when power is
applied and, when a battery is attached, that
the charger is in float mode. It lights yellow
when the unit is charging the battery. It
lights red to indicate a fault condition
(shorted/reversed output connector).
This unit is designed to automatically switch into a single stage, float charge mode when
the battery is charged. A single stage, parallel charger version is available for keeping a
battery fully charged when used with a permanent or intermittent parallel load. The use of
an optional low voltage cut out is recommended when using parallel loads. This unit is
not designed to operate as a standalone power supply.
ASSEMBLY INSTRUCTIONS
Loosen the screws on the charger output terminal
strip. Identify the polarity of the terminal strip ant
the output connector; both the charger housing
and the output cable are marked with “+” & “-”
symbols. Insert the two spade terminals under the
terminal strip screws and tighten. To prevent
accidental shorting, cover the exposed terminals
with the molded press-on terminal cover.
If using loose wires, insert stripped ends under washers. A cable having a shield may be
grounded to the bottom hole using a number 6-32 x ¼” machine screw.
OPERATING INSTRUCTIONS
Before using this battery charger, make sure it is compatible with your battery. Refer to
the ratings on the battery charger, the specifications in this manual, and your battery
documentation. Charge only sealed or valve regulated, lead-acid, non-automotive,
maintenance free rechargeable batteries. Attempting to charge other types of batteries
may result in battery damage.