FEATURES 

1. Operating Principle 

L2SW adopts the way to deliver DC voltage from the battery to LED device through  Step-

Down  circuit  and  generate  light  speed  through  the  lens.  Even  though  battery  voltage  is 

reduced, L2SW allows LED to provide consistent brightness.   

2. Electrical Rating 

1) DC Power Supply: Input 100-240 V~ (50-60 Hz, 0.3 A), Output 5 V 

, 2.2A 

2) Charger: Input-DC5V, 2.2A / Output-DC4.2V, 1.0A 

3) Battery Pack (BTPWL): DC3.7V 

  620mAh (Lithium Polymer) 

4) Battery Pack (BTPWS): DC3.7V 

  380mAh (Lithium Polymer) 

3. Protection Classification & Type against Electric Short 

1) Protection Classification: 

  LED Control Unit: Battery Operated Equipment 

  Medical power supply: Class II device 

2) Protection: N/A 

4. Safety Circuit: L2SW contains Latching Power Switch circuit and protection circuit for over 

current & overvoltage to keep the charging quantity. 

5. Block Diagram: Refer to below figure. 

 

Summary of Contents for L2SW

Page 1: ...LED Headlight System User Manual Optical Device Medical Device System Engineering XENOSYS CO LTD 2 Venture ro 100 Beon gil Yeonsu gu Incheon 22013 Korea TEL 82 32 875 9811 2 FAX 82 32 875 9813 www xe...

Page 2: ...e of Contents INTRODUCTION 3 SAFETY PRECAUTIONS 4 FEATURES 7 COMPONENTS 8 FUNCTIONS 9 OPERATING INSTRUCITON 12 BASIC TROUBLESHOOTING 16 SPECIFICATIONS 17 ELECTROMAGNETIC COMPATIBILITY 23 TRANSPORTATIO...

Page 3: ...is product is the medical device and KFDA approval registration is described like below table Registration No 1909 Certificate No Gyeongin Jesin 07 86 Product Category I A General Instruments Class Cl...

Page 4: ...avoid the humidity and water 4 Do not use in the presence of a flammable anesthetic mixture with air oxygen or nitrous oxide Warning for Power Unit 1 Do not use any undesignated DC power supply excep...

Page 5: ...se discoloration 7 Avoid the reach of children or pets 8 Maintain the following conditions for storing the product Environment for Storage Transportation Ambient Temperature 10 40 50 104 Relative Humi...

Page 6: ...s thus if the operating time is shortened after full charge we recommend exchanging new battery 7 Be careful on benzene thinner alcohol volatile flammable fluid and water If those chemicals penetrate...

Page 7: ...put 100 240 V 50 60 Hz 0 3 A Output 5 V 2 2A 2 Charger Input DC5V 2 2A Output DC4 2V 1 0A 3 Battery Pack BTPWL DC3 7V 620mAh Lithium Polymer 4 Battery Pack BTPWS DC3 7V 380mAh Lithium Polymer 3 Protec...

Page 8: ...OMPONENTS 1 Basic Components Main Body LED Control Unit LCUW Battery Pack BTPWL 2 pcs BTPWS 2 pcs Charger LCHW Medical DC Power Supply FW8000MUSB05 USB Power Cable USBC KOIKO Mini Driver DRV18 L2SW Un...

Page 9: ...y Pack BTPWS Refer to page 10 2 2 Charger LCHW Refer to page 11 1 Medical DC Power Supply FW8000MUSB 05 Refer to page 11 1 USB Power Cable USBC 1 KOIKO Mini Driver DRV18 1 Universal Clip 1 Anti curing...

Page 10: ...inal Adjustable link LED Lens module can move up down and left right side LED Lens Module LLMW Fix Tab hole Bolt position for universal clip or Xenosys TTL frame or loupe fix 2 Battery Pack Battery Ou...

Page 11: ...Connector Jack Connector jack between DC5V power supply and the plug Charging Terminal The charging will start when the battery has been put on the charger and connect DC5V power supply connected to t...

Page 12: ...The battery is not completely charged so charge them fully before the first time usage Connect power supply charger to supply the power If the battery is fully charged it will show green light on cha...

Page 13: ...water or electrolyte flow into the main body 6 In case of malfunctioning stop using immediately and contact the dealer 7 Do not disassemble repair or modify the equipment by unauthorized personnel Cau...

Page 14: ...ust the intensity change switch for desired brightness Below table will show you the operating time brightness lx WD400mm according to each step LED Lens Module LLMW Step Brightness lx WD400mm BTPWS O...

Page 15: ...Frame Attached with Universal Clip Pogo pin Battery Output Terminal E How to disassemble the battery pack 1 Sit on the battery pack to fit pogo pin of main body to the battery output terminal of batte...

Page 16: ...urn off Sit on battery to the charger to check remaining value Re charge the battery The light intensity is not enough Check the intensity is properly adjusted Adjust the intensity step Discharging ti...

Page 17: ...SW www xenosys co kr 17 BTPWS BTPWL SPECIFICATIONS 1 Measurement Weight A Main Body LED Control Unit LCUW Size Refer to below photo Weight 15 1 g B Battery Pack BTPWS BTPWL Size Refer to below photo W...

Page 18: ...www xenosys co kr 18 C Charger LCHW Size Refer to below photo Weight 24 g D Medical DC Power Supply FW8000MUSB 05 Size 31 L x41 W x77 H mm Weight 81 g The purpose of green LED is to indicate the powe...

Page 19: ...Wireless LED Headlight System L2SW www xenosys co kr 19 E USB Power Cable USBC Size 2m Weight 44 g F Anti curing Filter LF08 2 Size Refer to below photo Weight g...

Page 20: ...Li polymer Operating Time BTPWS Approx 5 hours 30 minutes 1st step mode Minimum Intensity Approx 2 hours 20 minutes 2nd step mode Approx 1 hours 30 minutes 3rd step mode Maximum Intensity Operating T...

Page 21: ...e LLMW 1st step 4 800 2nd step 10 000 3rd step 15 000 Field of View mm WD400mm 82mm Color Temperature Wavelength Range 6000 K 400 700 nm Visible Uniformity More than 80 WD400mm LED Life Span Guarantee...

Page 22: ...Wireless LED Headlight System L2SW www xenosys co kr 22 3 Labels A Outer Carton Box B LED Control Unit C Battery Pack...

Page 23: ...ption to some other equipment around It cannot guarantee that the interruption will not give any influence to specific equipment When the device is powered on you can find out if it generates electrom...

Page 24: ...e Ambient Temperature Relative Humidity Relative Humidity Pressure Pressure Environment for Transportation Storage Non operating Ambient Temperature Ambient Temperature Relative Humidity Relative Humi...

Page 25: ...process with excessive temperature and humidity In case of the exposure it will cause the damage to the equipment and out of warranty Especially inside parts of the main body do not allow the contact...

Page 26: ...om the abuse or improper use warranty will not be applied The repair cost shall be notified prior to the service repair work starts 10 Before sending the equipment need for repair contact the manufact...

Page 27: ...sys co kr 27 Revision List Version No Release Date Revison Version 1 0 March 12 2020 First version XENOSYS CO LTD 2 Venture ro 100 Beon gil Yeonsu gu Incheon 22013 Korea TEL 032 875 9811 2 FAX 032 875...

Reviews: