background image

66

General Information

Relative humidity is important to your health and home
as proper humidification helps reduce respiratory difficul-
ties and helps improve the indoor air quality.
A good relative humidity is one just high enough to barely
start condensation along the lower edges or lower
corners of the windows. More than that can be damag-
ing.
Frequent fogging or excessive condensation on inside
windows indicates the indoor humidity level is too high
for outdoor weather conditions. Damage to the building
may result if the condition persists. Condensation on
inside of storm windows indicates loose inside windows.
Adding weather-stripping to tighten inside windows
usually corrects this problem.
The following table shows the recommended maximum
indoor humidity in relationship to the outdoor tempera-
tures.

Outdoor

Humidity

Temperature

Single -Paned Double-Paned

Glass

Glass

+30°F

30%

50%

+20°F

20%

40%

+10°F

15%

35%

0°F

10%

30%

-10°F

5%

25%

-20°F

5%

20%

-30°F

3%

18%

Table 1

For Propane (LP) Installations Only

For furnaces operating on propane, please review the fol-
lowing warnings before use.

WARNING

To avoid death, personal injury or property damage
due to explosion or fire, install a gas detecting
warning device. Since the odorant  in propane gas
can be reduced by iron oxide (rust), a gas detecting
warning device is the only reliable method to detect
propane gas leaks.

WARNING

If  the gas furnace is installed in a basement, an
excavated area or a confined space, it is strongly
recommended to contact a propane supplier to install
a gas detecting warning device in case of a gas leak.

• Since propane gas is heavier than air, any leaking

gas can settle in any low areas or confined
spaces.

• Propane gas odorant may fade, making the gas

undetectable except with a warning device.

 

WARNING

An undetected gas leak will create a danger of
explosion or fire. If the presence of gas is suspected,
follow the instructions on the front cover of this
manual. Failure to do so could result in SERIOUS
PERSONAL INJURY OR DEATH.

Summary of Contents for XF8S

Page 1: ...tained Take time to familiarize yourself with the information concerning furnace installation features operation and maintenance contained within this manual 80 TWO STAGE GAS FIRED FURNACE User s Info...

Page 2: ...the customer This includes all safety precautions and related items Prior to actual installation thoroughly familiarize yourself with this Instruction Manual Pay special attention to all safety warnin...

Page 3: ...the furnace and to replace any part of the control system and any gas control having been under water Your warranty certificate is also supplied with the unit Read the warranty carefully and note what...

Page 4: ...use can shorten the life of the furnace and create hazards for you the homeowner General Information Unit Location 1 The furnace area and the vicinity of any other gas ap pliances must be kept clear...

Page 5: ...home and is warmed to 72 F the relative humidity will drop to 6 very dry if no more moisture is added General Information Check the burner flames for 1 Good adjustment 2 Stable soft and blue 3 Not cur...

Page 6: ...F 20 40 10 F 15 35 0 F 10 30 10 F 5 25 20 F 5 20 30 F 3 18 Table 1 For Propane LP Installations Only For furnaces operating on propane please review the fol lowing warnings before use WARNING To avoid...

Page 7: ...ical components are contained in both compartments To avoid electrical shock injury or death do not remove any internal compartment covers Contact a qualified servicer at once if an abnormal condition...

Page 8: ...ute wait ing period in Step 7 follow the instructions on the front page of this manual If gas can not be smelled Turn the gas control knob or lever counterclockwise to the ON position The knob or leve...

Page 9: ...reset temperature activated sensor This limit guards against overheating as a result of insufficient conditioned air passing over the heat exchanger Disconnect electrical power prior to removing the...

Page 10: ...t is made to engage the roll out protection device and turn the furnace back on Resetting From Lockout Furnace lockout is characterized by a non functioning furnace circulator blower may be running co...

Page 11: ...sonal injury due to electrical shock disconnect the electrical power before performing any maintenance If filter replacement becomes necessary it must be replaced with a filter of the same type and si...

Page 12: ...e same type and size To reinstall filter follow instructions included with external filter rack kit BE SURE AIRFLOW DIRECTION ARROW POINTS TOWARDS THE BLOWER When the filter is located in the bottom o...

Page 13: ...inspect the appliance and to replace any part of the control system and any gas control which has been underwater 1 STOP Read the safety information above on this label 2 Set the thermostat to lowest...

Page 14: ...ial Number of the unit must be supplied These numbers are recorded on the nameplate of the furnace For convenience record this information here MODEL NUMBER _ _ _ _ _ _ _ _ _ _ _ MANUFACTURING NUMBER...