11 - 4
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual Trigger Mode by scanning a Manual
Trigger Mode bar code (
), or by sending a serial menu command for
triggering (
). Once the scanner is in serial trigger mode, the trigger is
activated and deactivated by sending the following commands:
Activate:
SYN T CR
Deactivate:
SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see "Read Time-
Out" on page 4-9 for a description, and the serial command on
).
Resetting the Custom Defaults
If you want the custom default settings restored to your scanner, scan the
Acti-
vate Custom Defaults
bar code below. This resets the scanner to the custom
default settings. If there are no custom defaults, it will reset the scanner to the
factory default settings. Any settings that have not been specified through the
custom defaults will be defaulted to the factory default settings.
Note: If using a cordless system, scanning this bar code also causes both the
scanner and the base or Access Point to perform a reset and become
unlinked. The scanner must be placed in its base to re-establish the link.
If using an Access Point, the linking bar code must be scanned. See
beginning on page 3-1 for additional
information.
The charts on the following pages list the factory default settings for each of the
commands (indicated by an asterisk (*) on the programming pages).
Activate Custom Defaults
Summary of Contents for 1900
Page 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide...
Page 20: ......
Page 32: ...xii...
Page 72: ...2 24 1200 2400 4800 9600 19200 38400 57 600 115 200...
Page 118: ...3 40...
Page 148: ...4 30...
Page 174: ...6 20...
Page 238: ...7 64...
Page 258: ...8 20...
Page 262: ...9 4...
Page 268: ...10 6...
Page 312: ...11 44...
Page 350: ...A 14...
Page 353: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message...