Structure

                                                                     IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not place any product referred in this manual long-term in the extreme environment
6. Install in accordance with the manufacturer’s instructions.
7. Use accessories only specified by the manufacturer.
8. Refer all servicing to the qualified service personnel.Servicing is required when the product has been 
damaged in any way, such as handle or mortise is damaged,product has been exposed to rain or moisture, 
does not operate normally. 

                                                                                        INTRODUCTION
Congratulations on your selection of  the XEEDER Stand-alone keycard lock. This is a solution that replace 
traditional key locks and carry out a modern, efficient and safe management of  the rooms in family and 
apartment.
Before using the instrument, be sure to carefully read through the instructions contained in this manual.
Please keep all information for future reference.

                                                                
                                                                                               SAFETY
Xeeder Stand-alone keycard lock (RFID & IC) product has been designed with the highest concern for 
safety.However, any device,if used improperly, has the potential for causing unlock unable and indirect 
personal injury.
To help ensure accident-free operation, follow these guidelines:

1.Lock requires AA battery x4pcs to provide power keep running even not ready any card.
Alkaline battery is suggested for gives a long using term (10-12months).
2.Replace new battery on time if you get low battery alarm-3beeps and red flash when read card finished.
3.You have 200 times last unlocking chance since lock gives low battery alarm.
4.Do not use battery mix new and old. It may cause short circuit to lock eletronic part.
5.Lock’s latch part is in mechanically, You can unlock it by using emergency key in urgently.
6.This product was designed for indoor use only including home, office and apartment.

1

Keycard

open the door.

Family & apartment

Keycard lock

installed on the door 

stand-alone

lock

Summary of Contents for stand-alone keycard lock L5118-M1

Page 1: ...Manual Content Structure P1 Specifications P2 Mortise Panel size P3 Lock Install P4 Issue cards P5 Basic action P6 Maintenance P7 ...

Page 2: ...instructions contained in this manual Please keep all information for future reference SAFETY Xeeder Stand alone keycard lock RFID IC product has been designed with the highest concern for safety However any device if used improperly has the potential for causing unlock unable and indirect personal injury To help ensure accident free operation follow these guidelines 1 Lock requires AA battery x4p...

Page 3: ...08 IR series able All series able Hotel Mifare 1K IC SLE4442 card No Limited depends on the software control Issue Master card please read page 5 Specifications 2 Number of user Read Range Card format Unlock time Lock Driving Lock Type LED Melody sound Battery Life Low Battery Alarm Power Working Environment Software require Max 200 users keycard 1 0 4 0cm contactless RFID type lock customize in E...

Page 4: ...e configuration changes without notice is reserved Mortise Panel size 78 0mm 20 0mm 243 0m m Standard 5 latch Link to PCB board Link to battery pack 22 0mm 90 0mm 4 0mm 30 0mm 155 0mm 200 0mm Handle install Dead bolt install FRONT SIDE ROOM OUTSIDE BACK SIDE 3 Cylinder install Mortise model K2S Panel L5118 5218 M1 stand alone keycard lock ...

Page 5: ...12 Power connector of battery pack 13 Spindle of handle 14 Strike 15 Strike box 16 Cylinder cover a handle hole b deadbolt knob hole c cylinder hole 2 4 16 3 5 1 11 12 13 14 15 6 Lock Install BATTERY BATTERY BATTERY BATTERY 10 9 8 7 b c a 4 a b c ROOM OUTSIDE TOOLS This is a standard right lever lock The left is in reverse case Model K2S mortise requires door thickness at least 40 0mm For other th...

Page 6: ...aster card can generate 200 Guest cards Max for 1 same door BeepBeepBeep Beep You can generate several pieces guest card at one time during the 8 0sec Program mode will off while 8 0sec times up and you can t generate card anymore In case you have not finished all cards you can do make the lock in program mode again to continue With the same way you can delete a guest card or several at one time I...

Page 7: ...to make the latch keep retracting On Off PASSAGE mode Passage Normal card required unlock way beep Read guest card beep Read guest card again beep switch normal passage NO just shake handle to unlock No beep cycle switch on off passage mode by read Master card off passage mode and requires guest card to on passage mode to unlock 1 beep Normal open and always requires card to unlock 1 beep Normal o...

Page 8: ...cloth Can not clean by water acidity liquid and alcohol Maintenance 7 Every 6 months add machine oil to latch Battery pack TYPE B 1 Uninstall the flank plate 2 Take out battery pack and replace new 3 Recover 1 Release screws from back panel 2 Take out battery pack keep power connector linked and replace new 3 Recover Battery pack TYPE A It requres replace new battery after a long term using Usuall...

Page 9: ...2008 Xeeder Technology Co Limited All rights reserved 3rd Floor Huichang building Bantian Buji Longgang Shenzhen China Tel 0086 755 83663830 Fax 888 extension Email sales xeeder com www xeeder us ...