Intro
Dear Customer,
Thanks for choosing XDOM® PRO. This user manual in-
cludes important information regarding security and prop-
er installation of XDOM® PRO devices.
The package includes:
- n.1 module (also called “device”) XDOM® PRO
- n.2 supporting screws
Page 1: ...XDOM PRO User Manual...
Page 2: ...anks for choosing XDOM PRO This user manual in cludes important information regarding security and prop er installation of XDOM PRO devices The package includes n 1 module also called device XDOM PRO...
Page 3: ...rom wherev er in the world 24 hours per day 365 days per year After the XDOM PRO installation the user can monitor the ON OFF status of the connected equipment and change their status after login oper...
Page 4: ...No particular settings are required to the Wi fi router e g ports firewalls etc Indeed the adopted Cloud system is structured in order to simplify the installation operations Moreover the XDOM PRO ar...
Page 5: ...er usage Moreover the warran ty is no longer valid in case of incorrect installation i e any mounting operation different from the one described in this manual XDOM PRO can be installed even in pres e...
Page 6: ...elevators and similar systems not equipped with emergency opening ON OFF of systems that can put in danger persons or animals As mere example it is explicitly forbidden to install XDOM PRO to control...
Page 7: ...s available to direct usage from the cus tomer Therefore opening and manomission of the module can cause the warranty void Each XDOM PRO has the following features Line to 230VAC and Null connections...
Page 8: ...he touch control is not re quired e g within the electrical motors boxes TYPICAL USE SCENARIO XDOM PRO ZERO can be used to generate the pulse con trol signal for an electrical gate therefore replicati...
Page 9: ...for the remote control of a single electrical equip ment even if power demanding e g industrial machines via an additional external relay TYPICAL USE SCENARIO XDOM PRO ONE can be used to ON OFF a dom...
Page 10: ...rol of shutters or to control two different equipment but locat ed in the same zone e g opening close of an access gate and ON OFF of illumination of the same environment TYPICAL USE SCENARIO XDOM PRO...
Page 11: ...paces or to control two different equipment but lo cated in the same zone e g opening close of an access gate and ON OFF of illumination of the same environment via an additional external relay TYPICA...
Page 12: ...L3 L2 L1 Electrical supply 230 VAC 50 Hz Power absorption Up to 2A for single line Front glass colours White Black Operating temperature range 20 C 70 C Radio Protocol Wi fi Bluetooth Low Energy for s...
Page 13: ...ent Output lines have a maximum commutation of 2A when considering nominal 230V voltage To operate with pow er demanding loads it is necessary to place on the out put stage also power relays tailored...
Page 14: ...TION Do not connect output loads exceeding the maximum value allowed for XDOM PRO output lines N b to provide Cloud communication XDOM PRO shall be installed in areas with sufficient preferred Wi Fi n...
Page 15: ...NORMAL INSTALLATION 2A of absorbed current for output line NL L3 L2 L1 RELAY INSTALLATION 2A of absorbed current for output line NL COM NO COIL NC L3 L2 L1...
Page 16: ......