Input power supply electronics is suitable to operate in
AC voltage, even with severe fluctuations (100V -260V),
therefore also in case of particularly demanding equip-
ment.
Input power stage is protected with a non-replaceable fuse.
In case of fuse intervention, the XDOM® PRO device shall
be replaced.
Output lines not galvanically isolated, therefore the elec-
trical connection shall be strictly performed referring to
the schematics outlined in this document.
Output lines have a maximum commutation of 2A, when
considering nominal 230V voltage. To operate with pow-
er demanding loads, it is necessary to place on the out-
put stage also power relays, tailored for the equipment.
Installation
XDOM® PRO devices have been designed to be installed
within 503E boxes, as well as within larger electrical box-
es. Communication between XDOM® PRO and the external
environment occurs via Wi-Fi protocol, therefore XDOM®
PRO cannot be installed within metallic boxes or behind
large metallic objects that can compromise the communi-
cation capabilities. XDOM® PRO devices are self-powered
through the 230 VAC electrical network.