BNC

- Standard configuration provides  one HDSDI loop through from top stage up to two available. 

 
0B 306

- Recorder power (user selectable) 4.5, 7.2, 9, 14.4 volts output and video out to recorder. Video 

input to monitor on channel two

. Removed but can be added

 

 

Rear Battery Housing 

The rear battery housing can be moved in and out by loosening the two 10-32 SHCS. There are safety 
stops on the ends so the housi

ng will not slide off the rails. Over 4” of travel, increases your panning 

inertia 

 
Trim  Knobs 

The LEH comes set up with trim knobs on one side, they can be transferred to the other side of the sled 
by loosening the set screw and spinning off the knobs. The left-right drive shaft must be removed and 
reassembled on the opposite side. See 

“Swapping the inching knobs” 

 
Programmable Digital Level Placement  
There are two 4-40 drilled and tapped holes on each side of the LEH. These holes are aligned with the 
XCS PDL housing. The screws should not protrude into the LEH housing any longer than .1875

”. 

 

On Screen  (LCD) Text Messages 

Upon power up, 

the sled’s serial number 

#0000xxx

 and the software revision level are displayed  

rev.2.0

 

Listed here are on screen text messages and causes for the error message.  

BATT 1 CANNOT BE 24 VOLTS

- 24 volt battery connected to wrong battery plate, B3 only. 

BATT 2 CANNOT BE 24 VOLTS

- 24 volt battery connected to wrong battery plate, B3 only. 

    

Above two messages are each shown for a few seconds followed by a shutdown of the sled

 

24V Over Current Cycle Power-

 Over current draw on the system or dead short or more than 36 volt 

input. Turn off power, remove issue, and turn back on. 
 

12V Over Current Cycle Power

- Over current draw on the system or dead short or more than 18 volt 

input.  Turn off power, remove issue, and turn back on. 
 

LEH internal user selectable adjustments

 

 

To access the internal adjustments inside the LEH you first should remove it from the Center 

post.  Remove the six 

3/32” hex head screws holding the housing together. Lift up a few inches and turn it 

over. There will be 6 to 8 wires and 1 or 2 connectors depending on your options connecting the top half 
to bottom half. You now have access to make the following choice of adjustments. 

 
 

Removable  jumpers are used 

to set voltages for 

RECORDER’s  voltage output 

Three battery 

terminal blocks 

Summary of Contents for ULTIMATE 2 SLED

Page 1: ...ULTIMATE 2 SLED BY XCS INC MANUAL Rev 2 3 1 14 ...

Page 2: ... Camera platform rear view Camera platform left side view Camera platform right left side view 0B 304 1 Ground 2 14 Vdc 3 Video signal 4 Video gnd 9mm tapped plugged hole for 0B Lemo X3 Often used for 2 pin Tally connector Lower electronics housing front view 1B 308 1 Power gnd 2 14 Vdc 3 Video signal 4 Video gnd 5 6 7 not connected 8 Video out from recorder deck 0B 304 1 Ground 2 14Vdc 3 Video si...

Page 3: ...ill be glad to advise you on any maintenance of our equipment Proper care should be taken when shipping your equipment to protect it from shock damage At least 2 0 of a 4 lbs Ester foam or equal should surround your equipment at all times when shipping Case design is made so that the case will absorb the impact and the case will give up its life protecting the equipment inside Unlike any sled ever...

Page 4: ...e The stud is made from a soft zinc steel the insert in the stage is hardened stainless steel By design the Kipp handle s stud will wear out first After a few years if you are having to over tighten the Kipp handle and the dovetail is sliding in the platform or the clamp is hanging up on the stainless steel shoulder bolts you will need to simply adjust the two set screws that keep the clamp in ali...

Page 5: ...acing the camera plate on the cameras center of balance Add the flexibility of the sliding plate you will never again has to worry about finding a center balance You will find ENG video cameras Sony P5 55 Arri SR s and Aaton are all down the center of the plate Alexa F65 Panavision Arri and Moviecam are all camera right side heavy so the camera plate when screwed into the base will be off towards ...

Page 6: ... the standard 1875 through hole in this handle if you like to use a safety pin If you are using the Ergo handle you will not need the locking screw because you do not flip the handle over for low mode work Gimbal Cleaning Care You will find that you most likely will not be disassembling your gimbal and cleaning it very often In fact it may be years before you would need to do it if at all Place gi...

Page 7: ...to the hex head screw in the gimbal fork Remove the screw that holds the fork on the gimbal handle and set it aside The fork should separate from the spindle cleanly If the handle is stuck on the spindle you might re insert the screw half way and tap the top of the hex head wrench This will disengage the stainless steel spindle shaft from the fork Reassemble in reverse order You do not have to use...

Page 8: ...se spare screws are provided with the sled Dual Rod Monitor Support Arm XCS 2 Telescoping Carbon Fiber Post Bayonet mounted means never before has changing center posts been so easy When disconnecting from the UPC you will need to unscrew the knurled ring completely When disconnecting from the LEH you need only to turn the knurled ring 60 degrees and pull up on the post When connecting or disconne...

Page 9: ... 3 of those battery packs When you change batteries you change all batteries at once All batteries plugged in are monitored and selected by the computer to provide both 12 24 Vdc when selected based on power demand and batteries ability to deliver power The BMS displays the individual voltage of each battery plugged into the system in 12 Vdc mode and combined 12 and 24Vdc display in 24Vdc mode Sin...

Page 10: ...or the warning indicator as follows 12 volt mode Indicator blinks at 13 4 volts 24 volt mode Indicator blinks at 24 2 volts In 12 volt mode the 8 selectable settings are 12 4 12 6 12 8 13 0 13 2 13 4 13 6 13 8 volts In 24 volt mode the user selectable settings are 23 0 23 2 23 4 23 6 23 8 24 2 24 4 24 8 volts User has two different 8 position rotary switches labeled SW1 12 volt mode SW2 24 volt mo...

Page 11: ...e sled s serial number 0000xxx and the software revision level are displayed rev 2 0 Listed here are on screen text messages and causes for the error message BATT 1 CANNOT BE 24 VOLTS 24 volt battery connected to wrong battery plate B3 only BATT 2 CANNOT BE 24 VOLTS 24 volt battery connected to wrong battery plate B3 only Above two messages are each shown for a few seconds followed by a shutdown o...

Page 12: ...r needs There are two different settings one for 12 volt camera systems SW2 and one for 24 volt systems SW1 To set each LO battery indicator you simply need to turn the 8 position rotary switch label 0 8 that corresponds to a specific voltage There are two rotary switches inside the housing and a voltage value key that shows the rotary switch number and the voltage value it corresponds to photo be...

Page 13: ...ion with a 12 Vdc battery Battery terminal block 3 is the only terminal block that can accept a 12 or 24 volt battery Battery terminal block 1 2 will not allow the system to be powered by a 24 Vdc battery Instead the LCD will display a text message telling you that B1 or B2 CANNOT BE 24 VOLTS See photo above and turn the sled off Battery terminal block 1 can accept up to 18 Vdc Battery terminal bl...

Page 14: ... gap 0 001 measured at each set screw when manufactured Swapping the inching Knobs side to side The first photo is a cutaway of the LEH and shows you how the shaft sits It does screw through a plastic nut that means you will have to turn out the drive shaft and turn it back in There are three spacers on the drive shaft One on the inside end of the drive shaft and one under the knurled inching knob...