Copyright | C6EU SERIES Installation and Operation Manual, Version 1.6 13
3.4
Environmental data
Environmental Data
Ground load bearing
At least 450 kg
Ingression protection
IP 54
Temperature range – Operation
- 25 °C to + 50 °C,
- 40 °C to 55 °C (optional, with additional heat pump)
Temperature range – De-rating
+ 50 °C to +70 °C
Temperature range – Storage
- 40 °C to + 80 °C
Operating Relative Humidity
5 % to 95 %, no condensing on the surface
Storage Relative Humidity
95 %, no condensing on the surface
Humidity
Up to 95% no condensation on the surface
Operational noise level
<65 dB in rated output power
Atmospheric Pressure
79 KPa - 106 KPa
Altitude
2000 m (maximum altitude without power derating)
Network
GSM/WCDMA/LTE/4G/LAN
Table 3.4.1 Environmental data of C6EU
3.5
Technical Standards
The C6EU products were already approved by TÜV Rheinland according to the technical
standards below:
Technical Standards
Healthy, safety and general
requirements
EN 50385: 2017
EN 61851-1: 2011
EN 61851-23: 2014
EN 61851-24: 2014
EMC
IEC 61851-21:2018
EN 301 489-1 V2.2.0 (2017-03)
EN 301 489-3 V2.1.1 (2017-03)
EN 301 489-52 V1.1.0 (2016-11)
Radio
EN 300 330 V2.1.1 (2017-02)
EN 301 511 V12.5.1 (2017-03)
EN 301 980-1 V11.1.1 (2016-07)
EN 301 980-2 V11.1.2 (2017-08)
Table 3.5.1 Technical standard of C6EU
Summary of Contents for C6EU
Page 1: ...C6EU SERIES Installation and Operation Manual ENGLISH ...
Page 2: ......