XCESS SX 3 Installation & Operation Instructions Download Page 4

FEB/27/2004                                                    Art.Nr: 3300-6652 Kompaktalarm SX3

 

XCESS 

SX3 

Rev.1.0          

www.autoalarm24.de

 

 + 

 

Arming with Voltage Sensor Bypass 

Press the

   

and   buttons 

together

 

 

- F 

Arming with Pathway Illumination 

Press the

   

button first within 3 seconds 

press

 F

 

F -   

Silent Arm 

Press the

 F 

button first within 3 seconds 

press

 

 

 

Car Locator 

Upon 

Armed, 

Press and release 

momentarily

 

 (3 seconds) 

Panic 

Press and Hold   

button

 for 3 seconds 

 

Disarm System 

Press and release momentarily

 

 

- F 

Disarming with Pathway Illumination 

Press the

   

button first within 3 seconds 

press

 F

 

F -   

Silent Disarm 

Press the

 F 

button first within 3 seconds 

press

 

 

 
C.LED INDICATORS: 

LED Status 

Off Disarmed 
Slow flash 

Armed 

2 flashes... pause 

Zone 2 / Activated on the Blue wire  

3 flashes... pause 

Zone 3 / Activated on change in Voltage such as the interior light turning on. 

4 flashes... pause 

Zone 4 / Activated on the Shock Sensor 

5 flashes... pause 

Zone 5 / Activated on the Ignition Switch 

 

D. CHIRP INDICATORS:               E. PARKING LIGHT: 

Chirp Function 

Parking 

light 

Function 

1 chirp 

Arm 

1 flash 

Arm 

2 chirps 

Disarm 

2 flashes 

Disarm 

4 chirps 

Disarm / Triggered 

3 flashes 

Disarm / Triggered 

6 chirps 

Car locator 

 

12 flashes 

Car locator 

 

F. ACTIVE ARMING: 

1. Press   button on transmitter. 
2. The siren will chirp once and the parking light will flash once indicating the system is armed. The LED will begin to 

flash and the engine starter will be disabled.  

SILENT ARMING:

 

Press the 

button first, within 3 seconds press   button on the transmitter will arm your security 

system, No chirp sound will be heard, arm confirmation will be through the vehicles parking lights only. 

ARMING WITH NOISELESS MODE: 

With the system disarmed, press the   button once, the siren will chirp once. 

Within 3 seconds, press   button again. The siren will emit one short chirp indicating the system is set and will be fully 
armed in 5 seconds with the noiseless mode for one arming cycle. In this mode, whenever strong vibration or lesser 
vibration is presented to the protected vehicle, the shock sensor cannot trigger the system and just only emit a few warn 
away chirps. The only means of triggering is the voltage drop sensor. 

ARMING WITH THE TWO STAGE SHOCK SENSOR BYPASSED: 

With the system disarmed, press the   button once, the siren will chirp once. Within 5 seconds, press   button twice 
again. The siren will emit two short chirps indicating the system is set and will be fully armed in 5 seconds with the 
shock sensor bypassed for one arming cycle. In this mode, the shock sensor cannot trigger the system. The only means 
of triggering is the voltage drop sensor. 

ARMING WITH VOLTAGE SENSOR BYPASS: 

With the system disarmed, press   and    buttons at the same 

time. The siren will emit one short chirp indicating the system is set and will be fully armed in 5 seconds with the 
voltage sensor is bypassed. In this mode, the system cannot be triggered by a change in voltage. The only means of 
triggering is the shock sensor. 

ARMING WITH PATHWAY ILLUMINATION

: Press the   button once to arm the system, the siren will chirp 

once. Within 3 seconds, press 

F

 button. The siren will emit one short chirp and the parking light will be turns “ON” for 

30 seconds to illuminate your pathway.  

 

G. ACTIVE DISARMING: 

1. Press   button on the transmitter. 
2.  The siren will chirp twice and the parking light will flash twice indicating the system is armed. The LED will turn off 

and the engine starter disable relay will be enable allow the vehicle to start. 

Summary of Contents for SX 3

Page 1: ...e system is set up as voltage drop sensing the trunk and hood light if equipped will trigger the system when the openings are lifted There is no need to install pin switches D STARTER INHIBIT RELAY Mount the starter inhibit relay near the ignition switch harness under the dashboard You will have to locate and cut the low current starter wire later in the installation Secure the relay in a convenie...

Page 2: ...ctivated will cause the siren to chirp once for the first twice for the second and three times for the third If a fourth is attempted to be programmed the first will be erased and the fourth will move the other two forward in the program FEATURE PROGRAMMING A CHOOSING SIREN TONE 6 DIFFERENT SIREN TONE MULTI SIREN TONE 1 Within 10 seconds after disarming press and hold F buttons for 3 seconds then ...

Page 3: ... is set to react to a change in voltage 4 minutes after arming c If the siren emits three tones the unit is set to react to a change to delete the voltage drop trigger after arming 3 When you are satisfied with the setting press and hold F button of the transmitter until the unit emits two long chirps This indicates the unit is locking in the adjustment NOTE If there is no transmitter activity dur...

Page 4: ...MODE With the system disarmed press the button once the siren will chirp once Within 3 seconds press button again The siren will emit one short chirp indicating the system is set and will be fully armed in 5 seconds with the noiseless mode for one arming cycle In this mode whenever strong vibration or lesser vibration is presented to the protected vehicle the shock sensor cannot trigger the system...

Page 5: ...tected as follows 1 Light impacts the shock sensor will emit a warn away chirp 2 Heavy impacts Change in Voltage such as the interior light turning on Hood open if installed Trunk open if installed turns on the ignition switch will trigger the programmed sequence The starter disable relay if installed prevents the vehicle s starter from cranking The siren parking lights will turn on to alerting of...

Page 6: ...FEB 27 2004 Art Nr 3300 6652 Kompaktalarm SX3 XCESS SX3 Rev 1 0 www autoalarm24 de 6 2 This device must accept any interference received including interference that may cause undesired operation ...

Reviews: