Xcel-Arc VIPER Plasma CUT30 Operating Manual Download Page 13

13

Operating Procedure & Techniques 
for PLASMA Cutting

● 

Air pressure and volume

Air pressure, flow rate and air quality are critical to quality plasma cutting and consumable life span.

 

The required air pressure and volume can vary from model to model and the manufacturer will provide the specs.  
The volume capacity of your compressor is important, if you have a small compressor with exactly the same l/min rating as the 
plasma, then the compressor will run continuously when you are plasma cutting, a compressor with a l/min rating slightly higher 
than the plasma would be more adequate.  If you are doing a lot of cutting, cutting thick plate (same air consumption but slower cut 
speeds = longer cut time) then choose a compressor at 1.5 to 2 times the plasma system requirement.

● 

Air quality

Good air quality is essential to quality plasma cutting and consumable life span.
Compressors take in air at atmospheric pressure and increase the pressure and store it in a tank. Humidity in the air is condensed 
in the tank and in the airlines producing water, more so in humid environments.  Moisture that forms in air lines has a tendency 
to condense into larger drops when the air pressure decreases as it is entering the plasma torch. When these droplets enter into 
the high temperatures (as much as 11,000°C) in the plenum of the torch, they immediately break down into oxygen and hydrogen, 
which alters the normal chemical content of air in the torch. These elements will then dramatically change the plasma arc which 

causes the torch consumable parts to wear very quickly, alters the shape of the nozzle orifice, dramatically affecting cut quality in 

terms of edge squareness, dross formation, and edge smoothness. Minimising the moisture in the air supply is absolutely critical 
to quality plasma cuts and longevity of consumable parts. As a minimum be sure to drain the receiver (tank) on the air compressor 

at least daily.  Most air plasma systems from reputable manufacturers have an on board particulate filter and or a coalescing filter 

with an auto drain that will remove some moisture from the air supply. For home workshop and light industrial users the on board 

air filter is adequate. Most situations however will require additional filtration to prevent moisture from affecting the quality of the 

plasma cutter  and in most cases it is recommended to install a sub micronic particulate filter that is designed to trap water through 

absorption. This style of filter  has a replaceable filter cartridge that absorbs water and must be changed after it is near saturation, it 

should be installed close as possible to the air intake of the plasma cutter.

 

● 

Technique Tips

•  It is easier to pull the torch through the cut than to push it.
•  To cut thin material reduce the amperage until you get the best quality cut. 

•  Use the correct size tip orifice for the amperage being used.

 

•  For Straight cuts use a straight edge or cutting buggy as a guide. For circles, use a template or circle cutting attachment.

 

•  Check that the front end consumable parts of the plasma cutting torch are in good condition.

AT1000 Sub-Micronic Filter 

 Filter Element

Hold the torch vertical at the edge of the 

work piece and place the stand off guide on 

the workpeice.

Pull the trigger to start the arc.
Start cutting on the edge until the arc has 
cut completely through.

Then, proceed with the cut.

● 

Hand torch cutting technique

When cutting make sure that sparks are 
exiting from the bottom of the work piece.

If sparks are spraying up from the work
piece, you are moving the torch too fast, or
you don't have enough amps set.

Hold the torch vertical and watch the arc as
it cuts along the line.

● 

Starting a cut

 PLASMA CUT30

Summary of Contents for VIPER Plasma CUT30

Page 1: ...PLASMA CUT3O YEAR MACHINE WARRANTY 1 1 Please read and understand this instruction manual carefully before the installation and operation of this equipment Xcel Arc 2020 XA CUT30V Operating Manual...

Page 2: ...ture VIPER Plasma Cutters are manufactured and compliant with CAN CSA E60974 1 ANSI IEC 60974 1 AS NZ60974 1 guaranteeing you electrical safety and performance Air quality Good air quality is essentia...

Page 3: ...riptions 9 Set Up and Operating Procedure 10 11 Plasma Cutting Procedure Techniques 12 14 SC40 Plasma Torch Parts Breakdown 15 Trouble Shooting 16 Machine Warranty 17 18 Notes 19 PLASMA CUT30 REGISTER...

Page 4: ...nerated whilst welding or cutting keep your head out of the fumes Keep the working area well ventilated use fume extraction or ventilation to remove fumes and gases In confined or heavy fume environme...

Page 5: ...ssure If damaged a cylinder can explode Because gas cylinders are normally part of the welding process be sure to treat them carefully CYLINDERS can explode if damaged Protect gas cylinders from exces...

Page 6: ...er table This equipment is of automatic voltage compensation which enables the maintaining of the voltage range within the given range In case that the voltage of input power supply amperage exceeds t...

Page 7: ...aterial such as hafnium and cerium This insert erodes with use also the nozzle orifice will erode with use Quality of the air used is paramount to longer life of electrodes and nozzles in short clean...

Page 8: ...commend 7 5KVA minimum Tolerant to variable power supply Entry Level Inverter Plasma Cutter 30 Amp 230V Single Phase 12mm Cut on Mild Steel Product Code XA CUT30V K Standard Package includes VIPER CUT...

Page 9: ...ED ON 3 Amperage Control Dial 4 Torch connection 5 Output connector connect to the work piece 6 On Off switch 7 Primary power input cable 8 Regulator 9 Air supply connector inlet connection Note the a...

Page 10: ...hine using the on off switch located at the rear of the machine 3 Connect the machine to the correct power supply and switch on the machine using the on off switch located at the rear of the machine 1...

Page 11: ...r as when welding Plasma has high arc voltage if the job or bench is wet and you place your hand or arm on it you can become part of the circuit and receive a shock be sure you are wearing leather glo...

Page 12: ...xtent of the bevel of the cut The easiest way to reduce bevel is by cutting at the proper speed and height for the material and amperage that is being cut Correct torch height and square to the materi...

Page 13: ...supply is absolutely critical to quality plasma cuts and longevity of consumable parts As a minimum be sure to drain the receiver tank on the air compressor at least daily Most air plasma systems fro...

Page 14: ...erial When the pierce is complete proceed with cutting Safety Trigger Operation The Suregrip SC40 torch supplied with the Viper Cut 30 machine has a new design of safety trigger Just pull back on the...

Page 15: ...C40 Electrode 5 SC2506 SC40 Swirl Ring Spare Parts Part Number Description 6 SC2520 09 SC40 Cutting Tip 0 9mm 7 SC2530 6 SC40 Retaining Cap 8 SC2551 SC40 Cutting Buggy 9 SC2540 SC40 Stand Off Guide 10...

Page 16: ...epair D Low cutting output 1 Incorrect setting of CURRENT A control check and adjust to proper setting 2 Faulty components in unit return for repair E Difficult Starting 1 Worn torch parts consumables...

Page 17: ...chased the goods of any alleged defect shortage in quantity damage or failure to comply with the description or quote You shall also afford Esseti NZ Ltd the opportunity to inspect the goods within a...

Page 18: ...A TIG Welding Torch Consumables such as Tungsten Electrodes Collet Collet Body Alumina Nozzle Torch Head Torch Head water Cooled Torch Head Flexible Back Caps Gas Lens Torch Handle Cup Gasket Torch Bo...

Page 19: ...19 NOTES...

Page 20: ...20 Esseti New Zealand Limited PO Box 4189 Palmerston North 4442 Phone 06 355 1103 Fax 06 354 2437 Email sales esseti co nz www esseti co nz Xcel Arc Esseti NZ LTD 2020 New Zealand Limited...

Reviews: