Xcaper Industries XSMKIT Instructions Manual Download Page 7

 

 

EN 403:2004 also requires that leakage tests be performed on hooded devices to 
test for inward leakage in the breathing zone and the ocular zone.  As the Xcaper 
Enterprise Smoke Mask Kit comes with goggles, these tests were performed with 
over  20  test  subjects,  with  and  without  facial  hair,  eye  glasses  and  contact 
lenses.  These tests indicated that there was no leakage into either the breathing 
zone or the ocular zone.   
 
The  Xcaper  Enterprise  Smoke  Mask  has  been  shown  in  laboratory  tests  to  filter 
99.6% of particulate matter at a size of 0.3 microns which meets the requirements 
of EN 403:2004.  However, these tests were not performed in accordance with EN 
403:2004 which uses sodium chloride in accordance with the requirements of EN 
143.  Instead, the tests performed on the Xcaper Enterprise Smoke Mask utilized 
0.3 micron latex spheres.   
 

Field and Live Fire Testing 

The Xcaper Enterprise Smoke Mask has also been tested under live fire conditions by 
firefighting professionals in California, New York and Mexico.  Such conditions are not 
controlled to the extent they are during laboratory testing.  However, these tests provide 
additional evidence of the efficacy of the Xcaper Enterprise Smoke Mask.  These tests 
have  shown  the  Xcaper  Enterprise  Smoke  Mask  to  be  effective  against  the  harmful 
effects  of  smoke  for  a  minimum  of  15  minutes.    Do  not  attempt  to  use  the  Xcaper 
Enterprise Smoke Mask except in the case of an emergency. 

 
 

NOTES 

______________________________________________ 
______________________________________________ 

______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________
______________________________________________

 

Summary of Contents for XSMKIT

Page 1: ...SING THE XCAPER ENTERPRISE SMOKE MASK KIT THIS PRODUCT WILL PERFORM AS DESIGNED ONLY IF USED AND SERVICED IN ACCORDANCE WITH THESE INSTRUCTIONS IF USED OTHERWISE THE XCAPER ENTERPRISE SMOKE MASK KIT M...

Page 2: ...ygen Use only in adequately ventilated areas which conform to the appropriate standard Use strictly according to the instructions labels and limitations pertaining to this device The Xcaper Enterprise...

Page 3: ...rise Smoke Mask Kit has been tested in accordance with EN 403 2004 and is designed to provide respiratory protection for a minimum of 15 minutes from smoke carbon monoxide acrolein hydrogen chloride h...

Page 4: ...he elastic straps do not hold the mask snugly to the face of a child use a free hand to hold the mask on the child s face while evacuating the area Use of Goggles This product may not be suitable for...

Page 5: ...the mask and pull both straps over the back of your head The longer strap should go above your ears around the upper part of your head The shorter strap should go below your ears around the lower par...

Page 6: ...h Acrolein 100 ppm 0 5 ppm 3 8 ppm Hydrogen Cyanide 400 ppm 10 0 ppm 9 2 ppm Hydrogen Chloride 1 000 ppm 5 0 ppm 1 0 ppm Carbon Monoxide 2 500 ppm 200 0 ppm 115 0 ppm Laboratory testing performed at R...

Page 7: ...x spheres Field and Live Fire Testing The Xcaper Enterprise Smoke Mask has also been tested under live fire conditions by firefighting professionals in California New York and Mexico Such conditions a...

Page 8: ...filtration technology can provide protection against toxic gases and deadly particulates Our products address the occupational needs of firefighters law enforcement first responders and emergency serv...