tone=1.16,579,527,50 means that with a climb rate of 1.16m/s the vario will beep with a 
frequency of 579Hz, that the complete tone interval will last 527ms, and that the tone will be 
audible for 50% of the tone interval. This is a typical tone that is used when indicating climbing.  

tone=-3.0,280 means that with a sink rate of -3.0m/s a tone of 280Hz will be emitted. As soon as 
the sink rate changes the to

ne frequency also changes, depending on the configuration. It‘s a good 

idea to only set sink rate and frequency for the sink alarm, and not set tone interval and duty cycle. 
This creates a nicer sink tone (not that a sink tone is ever nice!) 

You can create your own tone settings using the tone simulator on 

www.xctracer.com

, however you 

can also copy and paste other people's tone settings to the configuration file. 

XC Tracer Mini II doesn't actually save the new configuration into its internal memory until it starts 
up in normal flight mode. So, press the red button briefly to unmount / eject the device from your 
computer, disconnect it from the USB cable, then turn XC Tracer Mini II on as normal. 

Important: Always close the configuration file before you unmount / eject XC Tracer Mini II!!!

   

 

Summary of Contents for Mini II

Page 1: ...User Manual XC Tracer Mini II Rev 02 4 6 2020 User Manual XC Tracer Mini II...

Page 2: ...cer Mini II before taking off you can switch it on whilst flying The vario won t beep on the ground but as soon as you re flying then XC Tracer Mini II will indicate the lift sink rate with beeping to...

Page 3: ...a 9 DOF IMU 9 Degrees Of Freedom Inertial Measurement Unit and from a pressure sensor to compute the real time climb rate and altitude avoiding the undesired time lag that conventional variometers suf...

Page 4: ...nough sunshine to power the device and charge the battery however it s always a good idea to switch off the device immediately after landing Should it ever be necessary you can charge XC Tracer Mini I...

Page 5: ...er of the variometer firmwareVersion XC_Tracer_Mini_II_R01 Indicates the device s firmware version reset no Setting reset yes resets XC Tracer Mini II to the factory default settings In order for this...

Page 6: ...ns ClimbToneOffThreshold 0 1 With this setting the vario will stop beeping when the climb rate is below 0 1m s You can also use negative values here for example 0 51m s when you use a thermal sniffer...

Page 7: ...od idea to only set sink rate and frequency for the sink alarm and not set tone interval and duty cycle This creates a nicer sink tone not that a sink tone is ever nice You can create your own tone se...

Page 8: ...already installed then XC Tracer Mini II will simply delete the firmware from the SD card It s impossible to install incorrect firmware on the XC Tracer Mini II all that happens is that the incompati...

Reviews: