Operating Limits
975-0128-01-01
4–3
Operating Limits
Power Output
The XPower Inverter 3000 Plus can deliver up to 2500 W continuous and
up to 3000 W for five minutes.
The wattage rating applies to resistive loads such as incandescent lights.
Input Voltage
The allowable inverter input (battery) voltage ranges are shown in the
following table:
Operating Condition
Voltage Range
Comment
Normal
10.5–15 V
Optimum
Performance
12.0–13.0 V
Low Voltage Alarm
11.0 V or less
The audible low battery alarm
sounds.
Low Voltage
Shutdown
less than 10.5 V The inverter shuts down to protect the
battery from being over-discharged.
High Voltage
Shutdown
15.0 V or more
The inverter shuts down to protect
itself from excessive input voltage.
Note:
Although the inverter
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.
XPower3000.book Page 3 Wednesday, December 10, 2003 6:52 AM
Summary of Contents for XPower 3000
Page 1: ...by XPower Inverter 3000 Plus Owner s Guide...
Page 8: ...viii...
Page 12: ...xii...
Page 34: ...3 16...
Page 40: ...4 6...
Page 44: ...5 4...
Page 46: ...A 2...
Page 58: ...C 4...