Commands and Queries Reference
Alphabetical
reference
OVSET?
return the current programmed value of the Power Module’s OVP
threshold. The result is a <value>.
Syntax:
OVSET?
<ch>
Parameters
the number of the channel to be queried.
Category Protection
Type:
Sequential
PEE
assign new value to the Primary Event Status Enable Register. Re-
calculates <rqs> and <ist>.
Syntax
PEE
<int>
Parameters
the value to be assigned to the Register - a decimal
number in the range 0 to 255 representing bits in the
Register.
Category Status
Type:
Sequential
PEE?
return the value of the Primary Event Status Enable Register. The
value returned is a decimal number in the range 0 to 255 representing
the bits of the Register.
Syntax
PEE?
Parameters none
Category Status
Type:
Sequential
PER?
return the value of the Primary Event Status Register. The value
returned is a decimal number in the range 0 to 255 representing the
bits of the Register. The register is cleared.
Syntax
PER?
Parameters none
Category Status
Type:
Sequential
POL
change the Power Module’s output polarity. This command requires
the presence of the Polarity Reversal Relay Option.
Syntax
POL
<ch>,<int>
Parameters
the number of the Power Module to be operated
upon.
the desired state of the Power Module’s output
polarity: a value of “0” means positive and a value
of “1” means negative output polarity.
Category Output
Type:
Overlapped
POL?
return the current output polarity of the Power Module.
Syntax
POL?
<ch>
Parameters
the number of the channel to be queried.
Category Output
Type:
Sequential
XMP 2600 Programming Manual
rev. 1.1
55