Xantrex 
XC3012, XC5012, 
XC1524 and XC2524

Battery Charger

12 V / 30 A 
12 V / 50 A
24 V / 15 A
24 V / 25 A

Owner’s Guide

XC_Charger_Owner.book  Page 1  Friday, August 12, 2005  3:23 PM

Summary of Contents for XC3012

Page 1: ...Xantrex XC3012 XC5012 XC1524 and XC2524 Battery Charger 12 V 30 A 12 V 50 A 24 V 15 A 24 V 25 A Owner s Guide XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 2: ...XC_Charger_Owner book Page 2 Friday August 12 2005 3 23 PM ...

Page 3: ...Xantrex XC3012 XC5012 XC1524 and XC2524 Battery Charger Owner s Guide XC_Charger_Owner book Page i Friday August 12 2005 3 23 PM ...

Page 4: ...24 Battery Charger Owner s Guide August 2005 Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX a MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDI...

Page 5: ...XC5012 XC1524 and XC2524 Battery Charger Installers should be certified technicians or electricians Organization This Guide is organized into 4 chapters and 1 appendix Chapter 1 Introduction Chapter 1 describes the XC Series standard features It also provides information to prepare for installation of the XC Series Chapter 2 Installation Chapter 2 provides procedures for installing testing and con...

Page 6: ... Charger 24 V 25 A will be referred to as the XC2524 when it is being referenced individually When the Xantrex XC3012 XC5012 XC1524 and XC2524 Battery Chargers are being referenced together they will be referred to as the XC Series Related Information You can find more information about Xantrex Technology Inc as well as its products and services at www xantrex com WARNING Warnings identify conditi...

Page 7: ... the responsibility of the installer to ensure that the installation of the XC Series complies with all relevant electrical codes 5 To avoid a risk of fire and electric shock make sure that existing wiring is in good condition and that wire is not undersized Do not operate the XC Series with damaged or substandard wiring 6 Do not disassemble the XC Series It contains no user serviceable parts Atte...

Page 8: ... Series has been approved as Ignition Protected It may be installed in areas containing gasoline tanks and fittings which require Ignition Protected equipment Xantrex recommends nevertheless that it is safest not to install electrical equipment in these areas 5 Make sure the area around the battery is well ventilated 6 Never smoke or allow a spark or flame near the engine or batteries 7 Use cautio...

Page 9: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation I...

Page 10: ...viii XC_Charger_Owner book Page viii Friday August 12 2005 3 23 PM ...

Page 11: ...l 1 7 Preparing for Installation 1 8 Tools and Materials 1 9 Location 1 10 Wiring Requirements 1 12 DC Wiring 1 12 AC Wiring 1 13 Battery Bank Size Requirements 1 14 2 Installation Installing the XC Series 2 2 Installation Sequence 2 2 Pre Installing DC Wiring 2 3 Pre Installing AC Wiring 2 4 Mounting the Remote Display 2 7 Mounting 2 8 Grounding 2 9 Final Connections 2 10 Final DC Connections 2 1...

Page 12: ...Reading Remote Display and Onboard Status Indicator Lights 3 11 Reporting While Charging or Equalizing 3 13 Reporting While Battery Monitoring 3 14 Reporting While Disabled 3 14 Using A Generator As Source Power 3 15 4 Troubleshooting Care and Maintenance 4 2 Indicator Light Flashing Sequences 4 3 Error Messages on Remote Display 4 4 Problem Solving 4 7 A Specifications Physical Specifications A 2...

Page 13: ...1 Introduction Chapter 1 describes the XC Series standard features It also provides information to prepare for installation of the XC Series XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 14: ... phase AC power outlet in the world invertable remote display panel which can also be removed from the charger and mounted up to 20 m 65 ft away for remote control and monitoring The XC Series provides the following protection features true fuseless reverse polarity protection to guard against continuous reverse battery polarity without charger damage AC over voltage protection shutdown over tempe...

Page 15: ...re 1 1 XC Series Item Description 1 Remote display for all programming functions and monitoring of the XC Series 2 Onboard status panel for monitoring charger status and charging current at the XC Series when the remote display is mounted remotely from the charger 3 Mounting flanges 2 1 3 XC_Charger_Owner book Page 3 Friday August 12 2005 3 23 PM ...

Page 16: ... display means that the button must be pressed and released before 2 seconds have elapsed Figure 1 2 XC Series Remote Display Item Description 1 ON STANDBY push button Press to turn on or disable the charger while AC power is connected Press and hold to apply selection when in setup or equalization mode Press to show battery bank voltages when AC is disconnected 2 Battery bank indicator lights Ill...

Page 17: ...icator lights Illuminate to show unit of measure for the numeric read out on the alpha numeric display 5 BANK selection push button Press to select a bank during setup Press at the same time as MODE to enter or exit equalization mode 6 TYPE selection push button Press to select flooded lead acid gel AGM or lead calcium batteries 7 MODE selection push button Press to select charging state during se...

Page 18: ... 2 Charger Status READY Ready indicator light illuminated indicates all batteries are fully charged and are now in float or rest 3 Charger Status CHARGING Charging indicator light illuminated indicates unit is performing a normal charge cycle Charging indicator light flashing indicates that the unit is performing an equalization cycle 4 Charger Status FAULT Fault indicator light continuously illum...

Page 19: ...nk 1 connector 3 BTS2 battery temperature sensor for bank 2 connector 4 BTS3 battery temperature sensor for bank 3 connector 5 Battery negative common for all 3 banks 6 mm stud 6 Battery positive for bank 1 6 mm stud 7 Battery positive for bank 2 6 mm stud 8 Battery positive for bank 3 6 mm stud 9 Fan assembly 10 Chassis ground earth for DC wiring 11 AC wiring access panel 2 Bank 3 Bank 1 4 3 2 8 ...

Page 20: ... Figure 1 5 XC Series System 1 AC mains source with correct size and type of circuit breaker 2 AC input wiring compartment 3 DC negative cable 4 DC positive cables 5 DC circuit breaker or DC fuse and disconnect 6 Battery or battery bank 7 Engine ground bus or DC negative bus 8 Remote display panel 9 Battery temperature sensor 1 is standard equipment 2 and 3 are optional 10 DC chassis ground earth ...

Page 21: ...e the information in AC Wiring on page 1 13 and your local electrical codes to determine the correct wire and breaker or fuse AC cable strain relief if the one included is not sufficient for your local electrical code requirements appropriately sized DC cables for each battery with suitable connectors at the battery end appropriately sized DC chassis ground earth with suitable connectors ring term...

Page 22: ...other form of conductive contamination Cool The ambient air temperature should be between 0 C 50 C 32 F 122 F for best performance Ventilated There must be at least 76 mm 3 in of clearance on each end of the XC Series for air flow Ventilation openings on the unit must not be obstructed If mounting in a tight fitting compartment the compartment must be ventilated with cut outs to prevent overheatin...

Page 23: ...Preparing for Installation 975 0187 01 01 1 11 Figure 1 6 XC Series Mounting Orientations ...

Page 24: ... 01 01 Wiring Requirements DC Wiring The following two tables show some typical wire sizes based on 3 voltage drop round circuit 75 C 167 F rated wire and wiring being inside the engine compartment assumed ambient of 50 C 122 F ...

Page 25: ...should be three conductor cable providing a line neutral and ground conductor or L1 N GND in an outer jacket For example in North America for 120 VAC use a 14 AWG wire with a 15 A breaker or typically in Europe for 230 VAC use either a 2 5mm2 wire with a 16 A double pole breaker or fuse or use 1 5 mm2 wire with a 10 A double pole breaker or fuse Note that every jurisdiction will have different req...

Page 26: ...igned to work with a minimum battery bank size Each bank should meet the minimum Ah rating shown in Table 1 2 Table 1 2 Minimum Battery Bank Size Models XC 1524 XC 2524 XC 3012 XC 5012 Minimum Battery Bank Size Ah 30 50 60 100 XC_Charger_Owner book Page 14 Friday August 12 2005 3 23 PM ...

Page 27: ... Owner s Guide AC cable strain relief Two DC cable boots Blank plate for remote display cavity One battery temperature sensor BTS Five 6 lockwashers Five 6 flatwashers Five 6 nuts After unpacking the unit record the serial number and other purchase information on page WA 4 of this guide XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 28: ...ctions at the charger page 2 4 4 Mount the remote display and charger in position page 2 7 5 Make the final DC and then AC cable connections including earth grounds page 2 10 WARNING Shock and Energy Hazards Be sure to read the safety guidelines and pay attention to all cautions and warnings throughout the installation procedure The installer is responsible for ensuring compliance with the install...

Page 29: ... with colored tape or similar kind of marking Repeat with a different color for the negative Most installation codes recommend coloring the positive red and the negative black 4 Install a DC circuit breaker or fuse disconnect in each positive cable close to each battery For your applications and jurisdiction consult your local electrical codes regarding the distance between the battery and the dis...

Page 30: ...e AC source by turning off the breaker feeding the circuit unplugging from shorepower and disconnecting any other power sources such as a generator 2 Plan the route that the AC wiring will follow from the source usually an AC distribution panel to the XC Series Measure and cut the required length of three conductor cable For example in North America for 120 VAC use a 14 AWG wire with a 15 A breake...

Page 31: ... Connect the AC wiring to the XC Series pigtail wires being sure to connect the line conductor to the line the neutral to the neutral and the ground to the ground The pigtail wires are color coded as follows 10 Make the connections with twist on or crimp on connectors or with other approved connectors suitable for your installation For example the ABYC Standards and Recommended Practices for Small...

Page 32: ... insulation tapers down as shown c Repeat Step b for the other end of the butt splice 11 Push the AC cable strain relief into the electrical junction box hole until it snaps into place 12 When all connections are completed push the wiring and connectors inside the wiring compartment Install the wiring compartment cover and fasten with the supplied blunt tip screws and lockwashers 13 Proceed to Mou...

Page 33: ...back of the display or blank plate 3 Line up the display or blank plate with the display socket making sure it is in the chosen orientation 4 Firmly press the flanges in place Do not press in the middle of the display 5 Route the display s North American style telephone type cable under the unit and plug the cable into the bottom connector on the rear panel of the unit WARNING Shock hazard Even if...

Page 34: ...ve the display as described on page 2 7 2 Secure the blank plate in the display socket as described 3 Ensure that the extension ca7 eure1 22f6 r 10o2 u 0 1 r 11 1 22 3 the 10 1 22 1 r 1 3 e the e n c 10l6 t 0os 6 e 101 1 222 m nunt1 22ing 1 22t 6 e 102 m p6 7 e S 6 a 1 ...

Page 35: ...d to ground in accordance with the applicable electrical codes this is usually a ground terminal in the AC distribution panel where the branch circuit originates Xantrex recommends that you install a DC chassis ground earth from the ground stud on the XC Series to the engine negative bus or DC ground bus The DC chassis ground earth should not be more than one size smaller than the power conductors...

Page 36: ...he DC cables AC cables and XC Series are all in place the final connection may be made Figure 2 1 shows the connection order Figure 2 1 DC Wiring Connection Order 5 2 6 3 7 4 8 9 10 12 13 14 1 11 15 XC_Charger_Owner book Page 10 Friday August 12 2005 3 23 PM ...

Page 37: ...4 Connect the free end of the negative cable to the negative terminal on the battery using sufficient torque as recommended by your battery manufacturer Note If you are using more than one battery you will need to connect the negative cable from each of the batteries to the negative ground bar or bus The negative ground bar or bus will then have a single negative cable connecting to the negative c...

Page 38: ...r codes on page 2 5 3 Secure cables in place using tie wraps P clamps or cable straps according to electrical codes Powering Up Make one last check that all connections and connectors are secure The XC Series charger may now be powered up Switch the AC power on at the source breaker It is normal to see a 7 10 second delay while the unit powers up During this time the indicator lights on the onboar...

Page 39: ...t this temperature the charging voltage is lower to keep batteries from overcharging charging will be slower and the batteries will be slightly undercharged One BTS is provided with with your XC Series and additional battery temperature sensors may be purchased separately To install a BTS 1 Switch off all devices operating from the battery 2 Connect the ring terminal on the sensor directly on to t...

Page 40: ...he DC connections to the charger feed the rubber boot over the charger end of the DC cables 2 Perform all other DC connections as described in To install DC wiring on page 2 3 3 After the DC cables are connected to the charger slide the boot up the cables and over the DC terminals If you are only using one battery slide the spare boots over the unused DC terminals XC_Charger_Owner book Page 14 Fri...

Page 41: ...ow which bank has been selected 4 Press TYPE repeatedly to select the battery type for each bank When you have selected a battery type that is different from the present configuration the bank indicator light flashes Set the TYPE according to the table below 5 Press and hold ON STANDBY until yes is displayed to store the selected battery type If no is displayed verify that you are setting the corr...

Page 42: ... a charging type that is different from the present configuration the bank indicator light flashes See About Charging on page 3 2 3 Press and hold ON STANDBY until yes is displayed to store the selected mode 4 At any time during setup you can press ON STANDBY once to cancel the current change and return to charging or battery monitoring XC_Charger_Owner book Page 16 Friday August 12 2005 3 23 PM ...

Page 43: ...3 Operation Chapter 3 describes the operating states and provides procedures for charging a battery and performing an equalization XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 44: ... and Float During the Bulk stage the battery is accepting high current In the Absorption stage the battery voltage is held constant and the current declines A battery will also gas produce hydrogen and oxygen during this stage Finally in the Float stage the charger continues to provide voltage at a lower level to maintain the battery in a fully charged state If there is no load on the battery it w...

Page 45: ...harger will automatically restart charging in order to refresh the batteries Charging Overview The XC Series will perform a battery detection sequence every 15 minutes or on reapplication of AC to determine which battery banks are present and healthy If you connect a battery when AC is disconnected the remote will not recognize it until the unit has performed a battery detection with AC applied To...

Page 46: ...t is later able to accept charge If disqualification occurs during Bulk or Absorption the battery is damaged or there is another charging source present other than the charger itself The remote display will show dis and the 25 Charge Current indicator light on the onboard status panel will flash Measuring Battery Voltage Use a voltmeter that has a stated accuracy of 0 5 or better on DC voltage Pla...

Page 47: ...be disqualified Because the charger is able to detect unhealthy batteries and disqualify them batteries that may have appeared healthy before will now be correctly identified as needing attention Perform these disqualification checks in the order shown 1 Wait 15 minutes for the next battery detection cycle The warning may be temporary 2 Verify that the battery meets the minimum AmpHour rating XC15...

Page 48: ...he AC breaker and or applying shorepower or turning the generator on The indicator lights will blink as an initialization sequence runs lasting typically 10 seconds After initialization the charging indicator light illuminates During charging the charging current indicator lights show the total current being delivered to the selected battery bank as well as any DC load applied 4 Re connect all loa...

Page 49: ...ode the XC Series is in float mode and will maintain the batteries charge Rest mode If you selected the 2 stage charging mode the ready indicator light shows the charger is now in rest mode and is checking battery voltage and elapsed time since the last charge cycle With either charging mode the XC Series will begin a charging cycle 21 days after the last cycle or when battery voltage drops to bel...

Page 50: ...a normal charge cycle on the batteries before you equalize them WARNING Explosion hazard During equalization the battery generates explosive gases Follow all the battery safety precautions listed in this guide Ventilate the area around the battery thoroughly and ensure that there are no sources of flame or sparks in the vicinity CAUTION Risk of battery damage The XC Series cannot automatically det...

Page 51: ...cel the equalization request by pressing ON STANDBY once If the battery cannot be equalized the display will show no Check that the battery is flooded and in float mode 6 When the charger is in equalize mode the display will show EQU 7 Monitor the specific gravity of each cell of the battery during equalization with a battery hydrometer The equalize cycle will terminate in one hour Check the speci...

Page 52: ...here is only one way to safely turn the XC Series off disconnect the AC power at the source and disconnect all DC batteries This is the only state where the XC Series is completely discharged When the XC Series is disabled or off the remote display is inactive WARNING Shock hazard The XC Series still has live voltage while disabled Even when AC power is removed if the XC Series is connected to a b...

Page 53: ...remote display is designed to report on the active status of the charger While the unit is charging the remote display reports only on the battery being charged at that moment It does not report the status of other batteries The Ready light on the onboard status indicator panel only illuminates when all connected banks have reached float flo of 3 stage charging or rest rdy of 2 stage charging If o...

Page 54: ...our seconds if bank 2 is being equalized and three times every four seconds if bank 3 is being equalized EQU Charging indicator light flashes Float mode of three stage charging or rest mode of two stage charging All batteries have been fully charged FLo or Rdy Ready indicator light illuminates A battery has been disqualified while in float mode of three stage charging or rest mode of two stage cha...

Page 55: ...the charging state for the bank presently being charged Charging for banks not in fault will continue see Error Messages on Remote Display on page 4 4 Charging for the bank in fault will resume once the fault condition is cleared Battery too hot fault ERR HoT Fault indicator light illuminated 100 current indicator light flashes Battery too cold fault ERR CLD Fault indicator light illuminated 10 cu...

Page 56: ... 2 Battery Voltage Bank 2 Charger Current Bank 3 Highest level bank fault or warning if present Bank 3 Charging Stage Bank 3 Battery Voltage Bank 3 Charger Current Reporting While Disabled If AC power has been disconnected or if you have used the remote display to disable the XC Series the unit is considered to be disabled The remote display is also disabled at this time While the XC Series is dis...

Page 57: ...ator As Source Power The XC Series can be run from a regular power source or from an alternate power source such as a generator Refer to Appendix A Specifications for AC input draw to determine the size of generator you need Many generators provide output voltage that is modified sine wave or modified square wave MSW rather than the true sine wave TSW that your utility provides The XC Series may b...

Page 58: ...3 16 XC_Charger_Owner book Page 16 Friday August 12 2005 3 23 PM ...

Page 59: ...4 Troubleshooting Chapter 4 contains information on error codes and procedures for troubleshooting your XC Series charger XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 60: ...ssolve To clean battery terminals 1 Disconnect all loads and charging sources 2 Using the appropriate tool remove the negative battery cable first and re install it last 3 To remove any stubborn residue sprinkle baking soda directly on the area scrub with a wet toothbrush or other soft bristle brush add water as required and then rinse 4 Reconnect the battery cable terminals to the battery lugs an...

Page 61: ...te display shows details of fault Example Err BAT PoL battery reverse polarity detected Fault indicator light flashes Charger fault condition remote display shows err followed by CHf The charger is damaged contact service Charging current indicator lights illuminate These lights indicate the charging current At transition points when the current is changing two indicator lights may flash alternate...

Page 62: ...rger Hardware Fault Call for service CHg Hot Over temperature Warning Allow the XC Series to cool Improve ventilation or install in cooler location If the temperature increases the XC Series will enter the fault level and stop functioning Err CHg Hot Red fault indicator light illuminated Over temperature Shutdown Allow the XC Series to cool Improve ventilation or install in cooler location CLd Gre...

Page 63: ...luminated Over Voltage Shutdown Warning Check battery Do not charge a battery rated at more than 12 volts nominal XC3012 XC5012 or 24 volts nominal XC1524 XC2524 Disconnect or turn off other charging sources such as the alternator or the charger on a generator with electric start If the warning level escalates without being corrected the XC Series enter the fault level and stop charging the affect...

Page 64: ...indicator light illuminated Green 100 indicator light flashes Display green bank indicator light for affected battery bank illuminated Battery too Hot Shutdown Allow battery to cool Improve ventilation or install in cooler location It may indicate a shorted cell in the battery or excessive water loss no Cannot apply change The operation you have tried to execute cannot be completed Err no Bat Red ...

Page 65: ...ion No power at AC source and no battery connected on bank 1 Defective AC wiring Charger level fault Ensure that power is available at the source and a battery or bank is connected on bank 1 Replace wiring Call for service Possible Cause Solution XC Series does not detect battery for one of following reasons poor connection reverse polarity connection damaged wiring XC Series internal temperature ...

Page 66: ...tery to cool Improve ventilation or install in cooler location It may indicate a shorted cell in the battery or excessive water loss Possible Cause Solution Battery temperature is too cold for safe charging Allow batteries to warm up before attempting to charge again Charging a battery that has frozen is a potential explosion hazard Possible Cause Solution Battery has a shorted cell Check the batt...

Page 67: ... Use a higher capacity charger Disconnect load or switch load off Replace battery Possible Cause Solution Battery is the wrong type or set to the wrong type to equalize Not all batteries are fully charged An active fault is present on the bank you are attempting to equalize Verify battery type is set to Gel or AGM These battery types cannot be equalized Wait for all batteries to be in float flo of...

Page 68: ...4 10 XC_Charger_Owner book Page 10 Friday August 12 2005 3 23 PM ...

Page 69: ...A Specifications Appendix A details the specifications for the XC Series XC_Charger_Owner book Page 1 Friday August 12 2005 3 23 PM ...

Page 70: ...ons Four right angle M6 studs 3 positives and 1 common negative for battery cable ring terminals and one M6 mm DC equipment ground Number of battery bank outputs 3 isolated independently controlled outputs Nominal battery voltage 12 V units 12 VDC 24 V units 24 VDC Normal operating output range 12 V units 0 16 VDC 24 V units 0 32 VDC Nominal operating AC voltage 110 240 VAC Rated DC output current...

Page 71: ...e current draw with remote installed XC3012 20 mA XC5012 20 mA XC1524 15 mA XC2524 15 mA AC input voltage range 100 260 VAC at full power 90 105 VAC at 80 restricted load Note Charger may not start with input voltage 100 VAC Maximum AC input current at 100 VAC at 184 VAC XC3012 6 AAC XC3012 4 3 AAC XC5012 10 AAC XC5012 5 7 AAC XC1524 6 AAC XC1524 4 3 AAC XC2524 10 AAC XC2524 5 7 AAC Power factor a...

Page 72: ...n voltage It will restart when this voltage is 0 2 V Output current limit XC3012 30 33 ADC XC5012 50 55 ADC XC1524 15 16 5 ADC XC2524 25 27 5 ADC Over temperature Internal charger temperature is measured Unit shuts down and restarts as follows Over temperature shutdown at 75 C 167 F Over temperature restart at 70 C 158 F Current derating in ambient temperatures Rated current to 50 C 122 F 2 C dera...

Page 73: ...1 EN60335 2 29 Battery Chargers ISO 8846 Ignition Protection for Small Craft ABYC E11 Alternating Current and Direct Current Electrical Systems on Boats ABYC A20 Battery Charging Devices NFPA70 1996 US NEC for home and RV installation requirements EMC FCC Class B CE marked meeting EMC Directive 89 336 EEC referencing EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 ...

Page 74: ...A 6 XC_Charger_Owner book Page 6 Friday August 12 2005 3 23 PM ...

Page 75: ... both parts and labor necessary to repair the product and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service for details on our freight policy for return shipments outside of the contiguous United States and Canada How do you get service If your product r...

Page 76: ...PARTICULAR PURPOSE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRAC...

Page 77: ...failure and or reason for the return A copy of your dated proof of purchase When you ship 1 Package the unit safely preferably using the original box and packing materials Please ensure that your product is shipped fully insured in the original packaging or equivalent This warranty will not apply where the product is damaged due to improper packaging 2 Include the following The RMA number supplied...

Page 78: ...harger has been installed ___________________________________________ Battery battery bank size ___________________________________________ Battery type e g flooded sealed gel cell AGM ___________________________________________ DC wiring size and length ___________________________________________ Description of light indicators or remote display readout ___________________________________________...

Page 79: ...XC_Charger_Owner book Page 5 Friday August 12 2005 3 23 PM ...

Page 80: ...world Fax 1 800 994 7828 toll free North America 34 93 473 6093 Europe 1 360 925 5143 direct and rest of world Email customerservice xantrex com North America support europe xantrex com Europe customerservice xantrex com rest of world 975 0187 01 01 Printed in Canada XC_Charger_Owner book Page 6 Friday August 12 2005 3 23 PM ...