4.0 OPTIONS
37
Mounting the CM/R
The CM/R is a remotely-mounted digital LCD multimeter, which can be
permanently installed in a wall or cabinet. The unit can also be surface-
mounted with relief behind it, and it can be located up to 1000 feet (305 meters)
from the C-Series controller itself. If the CMR appears inaccurate or unusual on
runs over 100 feet from the controller, remove the jumper located below the
voltage configuration pins on the back of the CM/R. This dims the LCD
backlight, reduces power consumption and improves meter accuracy.