Installation and Configuration
Initial Inspection
22
Operating Manual for RS-232 for XHR/XFR Series Power Supply
Figure 2.3
RS-232 Interface PCB
JUMPER SELECTION
J65
Local OVP control selection
[closed] [default]. See page 32.
[open] Front Panel OVP Control.
J93
User TTL shutdown (S/D)
selection
[1-2] User TTL S/D line active low. See page 35.
[2-3] [default] User TTL S/D line active high.
J103
Remote OVP Control Selection
[closed] [default]. See page 32.
[open]
J216
RS-232 (J5) transmit and
receive pin selection
[3-1] Receives on pin 3 (TXD) [default]
[4-6] Transmits on pin 2 (RXD) [default]
[3-5] Receive on pin 2
[4-2] Transmit on pin 3
J217
RS-232 flow control selection of
RTS/CTS (ready to send/clear
to send) or DTR/DSR (data
terminal ready/data set ready)
[1-3][4-6] [default] RTS input on pin 7 (used with
CTS output on pin 8)
[3-5][4-6] DTR input on pin 4 (used with DSR
output on pin 6)
J218
RS-232 flow control selection of
RTS/CTS or DTR/DSR
[2-4][[3-5] [default] CTS output on pin 8 (used
with RTS input on pin 7)
[2-4][1-3] DSR output on pin 6 (used with DTR
input on pin 4)
Note: All other jumpers are not user-selectable.
LED INDICATORS
CR89
Red Diagnostic LED
Bus error or soft restart on Slave circuitry.
CR166
Red Diagnostic LED
Soft restart on Master circuitry.
CR167
Green Diagnostic LED
Bus error on Master circuitry.
EPROMS
U117
Slave EPROM
See revision number stamped on EPROM.
U191
Master EPROM
See revision number stamped on EPROM.