DIP Switch Settings
26
Prosine 2.5/3.0 Installation & Operation Guide
SWITCH BANK 1 (SW1)
Battery Type
Switch 1
❃
UP
Flooded
DOWN
Gel
Not used
Switch 2
Switch 3
Switch 4
Battery Temperature
Switch 5 and
Switch 6
❃
UP
❃
UP
Warm, usually 50–80 °F / 10–27 °C
DOWN
UP
Cold, usually below 50 °F / 10 °C
UP
DOWN
Hot, usually above 80 °F / 27 °C
DOWN
DOWN
Warm, usually 50–80 °F / 10–27 °C
Load Sense
Switch 7 and
Switch 8
❃
UP
❃
UP
0 Watts. Load sense is disabled
DOWN
UP
10 Watts
UP
DOWN
25 Watts
DOWN
DOWN
50 Watts