Adjusting Feature Settings in Configuration Mode
56
Freedom XC 2000 (230VAC) Owner's Guide
Settings
Setting Name
Setting
Number
Default
Value
Range of
Values
Description
Inverter Ignition Control
01
OFF
OFF
LOT
ATO
See
Description of Ignition Control Features on page 42
LBCO Voltage
02
10
.
5
10
.
0
to
12
.
8
The voltage setting value can be adjusted by 0.1 increments. The
inverter is able to recover automatically at LBCO v 2.0 V
(default).
LBCO Shutdown Delay
Timer
03
10
0
to
600
When the range is from 1 to 20, the timer setting value can be
adjusted by 1-s increments. When the range is from 20 to 300, the
timer setting value can be adjusted by 10-s increments.
LBCO Recovery Voltage
04
13
.
1
10
.
2
to
16
.
0
The range is from LBCO v 0.2 to 32, adjusted by 0.1
increments. Selecting a higher value than the battery’s actual fully-
charged voltage level will disable the auto-recovery feature. You
may manually reset the inverter/charger when the low battery cut
off event occurs.
Power Save Time
05
25
OFF
,
1
to
25
The range is from 1 to 25, adjusted by 1-h increments. The next
setting after 25 is OFF.
Power Save (Load
Sensing) Mode
06
dIs
ENA
(enable)
,
DIS
(disable)
When enabled, the inverter/charger’s “no load” loss can be
reduced further when total load is less than 25 W.
Summary of Contents for Freedom XC 2000
Page 1: ...Freedom XC 2000 230VAC Inverter Charger Owner s Guide Freedom XC 2000 230VAC 817 2080 12...
Page 20: ...This page is intentionally left blank 2...
Page 28: ...This page is intentionally left blank 2...
Page 32: ...This page is intentionally left blank 2...
Page 98: ...This page is intentionally left blank 2...