Basic Installation Procedures
24
Freedom XC 1800 (12VDC) Owner's Guide
NOTICE
EQUIPMENT DAMAGE
Make sure the wires are connected properly. The AC wiring
terminal blocks are split into input and output sections.
Failure to follow these instructions can result in equipment
damage.
When making the AC input and AC output connections, observe the
correct color code for the appropriate AC wire, as described in
below.
Color
AC Wire
Black/Red/Brown
Line
White/light blue
Neutral
Green, green/yellow, or bare
copper
Ground
Table 8 Color codes for typical AC wiring
NOTICE
REVERSE POLARITY DAMAGE
Make sure the wires are connected properly. Improper connections
(connecting a line conductor to a neutral conductor, for example)
will cause the Freedom XC to malfunction and may permanently
damage the inverter/charger. Damage caused by a reverse polarity
connection is not covered by your warranty.
Failure to follow these instructions can result in equipment
damage.
AC Input Connections
To make a connection:
1. Ensure AC and DC power sources are turned off.
2. Install the required circuit breaker in the AC distribution
panel supplying AC power to the unit.
3. Attach the compatible connector from the AC input cable to
the receptacle on the unit as shown.